Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T02CM03479
Permit Details
Apply Date:
07/23/2002
Applicant:
FROST, MARC CAHILL
Description:
TI:OFFICE
Contractors:
- LLOYD CONSTRUCTION COMPANY INC ,
Permit Reviews
Permit Number - T02CM03479
Permit Status: Final
Permit Description: TI:OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/07/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 07/22/2003 | COMPLETED |
07/23/2002 | 3RD PARTY COMMERCIAL TI | 09/09/2002 | COMPLETED |
09/11/2002 | RESUBMITTAL | 01/17/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM03479
Permit Status: Final
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/23/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02CM03479
Permit Description: TI:OFFICE
Total Completed Inspections - 33
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/05/2003 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*1.) BLDG "C" N/H UNDERGROUND OK WATER TEST ONE RISER TO TEN FEET OK OK TO BACKFILL. 2.) BLDG "B" WATER SERVICE UNDERSLAB OK TO COVER. |
04/13/2003 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000*4" ABS SCH 40 SEWER FROM 2 WAY CLEAN OUT TO TRANSITION TO DIP OK. WATER TEST OK OK TO BACKFILL 2.) NEED TO SEE DIP AND TIE-IN AT MANHOLE. |
07/11/2003 | ROOF NAILING | HLEYVA | Approved | IVRS - Inspection 0000* |
07/11/2003 | EXT METAL CLIPS/EXT SHEATHING | HLEYVA | Approved | IVRS - Inspection 0000* |
09/08/2003 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
09/08/2003 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
09/22/2003 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*/ PLUMBING YARDWATER FROM METER THRU RPPBP AND CONNECTED TO BLDG SUPPLY OK. PRESSURE TEST OK. TRANSITION FITTINGS OK. OK TO COVER. |
10/30/2003 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
10/30/2003 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
03/11/2004 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000* |
06/30/2004 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
07/26/2004 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
07/26/2004 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | |
07/26/2004 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection :*/ 1) VERY LIMITED MECH ONLY 2) SHELL ONLY |
07/27/2004 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection :*/ 1) PLUMBING FINAL IS OK 2) OK FOR C OF O |
08/02/2004 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection :* |
08/02/2004 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection :* |
08/02/2004 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection :* |
08/02/2004 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | IVRS - Inspection :* |
08/03/2004 | ELECTRIC - UFER | MCAPISTR | Approved | |
08/03/2004 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | |
09/03/2004 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection :* |
09/03/2004 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection :* |
09/03/2004 | FRAMING | AMATHIES | Approved | IVRS - Inspection :* |
09/03/2004 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection :* |
09/03/2004 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | IVRS - Inspection :* |
09/03/2004 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection :* |
09/03/2004 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection :* |
09/03/2004 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
09/13/2004 | FIRE - FINAL | LTHOMAS | Approved | |
11/09/2004 | ENGINEERING - FINAL | DROBERTS | Approved | OK TO CLEAR |
11/10/2004 | RIGHT OF WAY - FINAL | MOTERO | Approved | CLEAR |
11/12/2004 | PERMIT FINALED | TACHONG | Approved |