Permit: T02CM03179
Permit Details
Apply Date:
07/02/2002
Applicant:
A P S ENERGY SERVICES CO
Description:
NEW:STORAGE
Contractors:
- A P S ENERGY SERVICES CO
Permit Reviews
Permit Number - T02CM03179
Permit Status: Final
Permit Description: NEW:STORAGE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/02/2002 | 3RD PARTY REVIEW-COMMERCIAL | 08/15/2002 | COMPLETED |
| 08/15/2002 | RESUBMITTAL | 08/19/2002 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T02CM03179
Permit Description: NEW:STORAGE
Total Completed Inspections - 19
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/25/2002 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000*ROOF NAILING APPROVED PER 51.2. I STILL NEED TO SEE SPECIAL INSP. REPORT FOR WELDS. |
| 09/25/2002 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection 0000*CANCELLED BY CONTRACTOR. |
| 09/26/2002 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
| 10/01/2002 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 10/24/2002 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | IVRS - Inspection 0000* |
| 10/24/2002 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection 0000* |
| 11/13/2002 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | IVRS - Inspection 0000*1.) 4" WELD GAS PIPE TO COENEVATION UNIT OK PRESSURE TEST 60# OK 2.) HAVE STATE INSPECT ENGINE. 3.) AFTER MECH INSP. GIVES OK CALL FOR GAS CARD. |
| 11/13/2002 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 11/13/2002 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection 0000* |
| 11/24/2002 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*1.) GAS & WATER FOR CO-GENERATION UNIT OK PRESSURE TEST OK BACKFLOW PROTECTION OK GAS IS ON. |
| 12/11/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
| 12/12/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | OUTDOOR LIGHTING FINAL | RMAJUTA | Approved | |
| 12/20/2002 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | |
| 12/23/2002 | PERMIT FINALED | RMYERS | Approved | |
| 12/23/2002 | FIRE - FINAL | LLAKEY | Approved | |
| 12/23/2002 | PLUMBING - INTERMEDIATE | RMYERS | Approved | |
| 12/23/2002 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | |
| 12/23/2002 | BUILDING - FINAL | LHANLY | Approved |