Permit: T02CM02773
Permit Details
Apply Date:
06/06/2002
Applicant:
N/A
Description:
APARTMENTS:NEW
Contractors:
- B F L CONSTRUCTION CO INC ,
Permit Reviews
Permit Number - T02CM02773
Permit Status: C of o
Permit Description: APARTMENTS:NEW
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/06/2002 | 3RD PARTY REVIEW-COMMERCIAL | 08/27/2002 | COMPLETED |
| 08/27/2002 | REVISION | 09/04/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02773
Permit Status: C of o
Permit Description: APARTMENTS:NEW
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/06/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM02773
Permit Description: APARTMENTS:NEW
Total Completed Inspections - 31
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/09/2002 | PLUMBING - YARD WTR LINE/TEST | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 10/10/2002 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection 0000*OK 3-2" PVC UNDER SLAB. |
| 10/17/2002 | PLUMBING - SEWER HCS CONNECT | FMCCLURE | Approved | IVRS - Inspection 0000* |
| 10/17/2002 | PLUMBING - ROUGH, SOIL | FMCCLURE | Approved | IVRS - Inspection 0000*SEWER INSTALLED TO PAINT OF CONNECTION. NEED INSPECTION OF CONNECTION. |
| 10/17/2002 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
| 10/17/2002 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* |
| 10/18/2002 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection 0000*OK 3/0 20' IN FOOTING. |
| 11/06/2002 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | IVRS - Inspection 0000* |
| 12/06/2002 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 12/06/2002 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 12/13/2002 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 12/13/2002 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000*PLEASE PROVIDE A PRESSURE TEST ON COMPLETE SYSTEM OF NOT LESS THEN 10LBS. 2.) ALL FIXTURES TO BE INSTALLED AT TIME OF FINAL 3.) APPROVED GAS VALVES FLEX TO BE ON JOB AT TIME OF FINAL |
| 12/13/2002 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000*ABS ONLY TEST OK. |
| 12/13/2002 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 12/23/2002 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000*OK ROUGH ELECT. |
| 12/27/2002 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
| 12/30/2002 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | IVRS - Inspection 0000*FINISH WIRING IN METER SOCKET. |
| 12/30/2002 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 02/10/2003 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
| 02/10/2003 | NPPO - FINAL | PGILBERT | Approved | |
| 02/10/2003 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
| 02/10/2003 | ENGINEERING - FINAL | JBRUCKME | Approved | |
| 02/10/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
| 02/10/2003 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 02/13/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
| 02/14/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 02/18/2003 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection 0000*SUBJECT TO BLDG INSP. RAMP FOR HC SHOWER. |
| 02/20/2003 | LANDSCAPE - FINAL | PGILBERT | Approved | |
| 02/21/2003 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 02/26/2003 | PERMIT FINALED | AQUIROZ | Approved |