Permit: T02CM02409
Permit Details
Apply Date:
05/14/2002
Applicant:
WATSON, JAMES RICHARD
Description:
TI:LAUNDRY
Architects:
- WATSON, JAMES RICHARD
Contractors:
- KACHINA GENERAL CONTRACTORS L L C
Permit Reviews
Permit Number - T02CM02409
Permit Status: C of o
Permit Description: TI:LAUNDRY
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/14/2002 | 3RD PARTY COMMERCIAL TI | 07/15/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02409
Permit Status: C of o
Permit Description: TI:LAUNDRY
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/14/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM02409
Permit Description: TI:LAUNDRY
Total Completed Inspections - 27
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/15/2002 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) THIS CODE VIOLATION HAS BEEN APPROVED BY DAVE MANN. SEE ATTACHED SHEET OF APPROVAL. |
08/22/2002 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
08/22/2002 | FRAMING | AQUIROZ | Approved | IVRS - Inspection 0000* |
08/26/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000* |
08/26/2002 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000*1.) WASTE & VENT SYSTEM IS OK 2.) OVERHEAD WATER DISTRIBUTION IS OK. 3.) OK FOR DRYWALL. |
09/11/2002 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
09/12/2002 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000* |
09/12/2002 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000*MUST HAVE ALL FIXTURES INSTALLED @ TIME OF INSPECTIONS. |
09/12/2002 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000* |
09/12/2002 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000* |
09/13/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
09/13/2002 | LANDSCAPE - FINAL | PGILBERT | Approved | N/A |
09/13/2002 | ENGINEERING - FINAL | LMAKUS | Approved | |
09/13/2002 | FIRE - FINAL | LTHOMAS | Approved | |
09/13/2002 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
09/13/2002 | PLUMBING - FINAL | TRINIVJR | Approved | |
09/13/2002 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | 1.) PLBG. FINAL IS OK 2.) NOTE: GAS INSPECTION UP TO BOILER IS OK SATE INSPECTOR HAS REQUIRED TO OWNER THAT THE BOILER BE ENERGIZED PRIOR TO HIS INSPECTION. SUBJECT TO THIS REQUEST UTILITY CLEARANCE CARD HAS BEEN RELEASED. |
09/13/2002 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
09/13/2002 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
09/13/2002 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
09/13/2002 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection 0000* |
09/13/2002 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection 0000* |
09/16/2002 | PERMIT FINALED | JYBARRA | Approved | |
09/16/2002 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
09/16/2002 | SIGN - FINAL | JYBARRA | Approved | |
09/17/2002 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000*OK C OF O. |
09/17/2002 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000*OK C OF O. |