Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
05/14/2002
Applicant:
WATSON, JAMES RICHARD
Description:
TI:LAUNDRY
Architects:
  • WATSON, JAMES RICHARD
Contractors:
  • KACHINA GENERAL CONTRACTORS L L C

Permit Reviews

Permit Number - T02CM02409
Permit Status: C of o
Permit Description: TI:LAUNDRY
Start Date Submittal Complete Date Status  
05/14/2002 3RD PARTY COMMERCIAL TI 07/15/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM02409
Permit Status: C of o
Permit Description: TI:LAUNDRY
Total Outstanding Activity Conditions - 1
Date Name
05/14/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T02CM02409
Permit Description: TI:LAUNDRY
Total Completed Inspections - 27
Date Description Inspector Results Comments
08/15/2002 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) THIS CODE VIOLATION HAS BEEN APPROVED BY DAVE MANN. SEE ATTACHED SHEET OF APPROVAL.
08/22/2002 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection 0000*
08/22/2002 FRAMING AQUIROZ Approved IVRS - Inspection 0000*
08/26/2002 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection 0000*
08/26/2002 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection 0000*1.) WASTE & VENT SYSTEM IS OK 2.) OVERHEAD WATER DISTRIBUTION IS OK. 3.) OK FOR DRYWALL.
09/11/2002 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection 0000*
09/12/2002 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection 0000*
09/12/2002 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved IVRS - Inspection 0000*MUST HAVE ALL FIXTURES INSTALLED @ TIME OF INSPECTIONS.
09/12/2002 PLUMBING - ABOVE CEILING TRINIVJR Approved IVRS - Inspection 0000*
09/12/2002 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection 0000*
09/13/2002 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0000*OK FOR C OF O.
09/13/2002 LANDSCAPE - FINAL PGILBERT Approved N/A
09/13/2002 ENGINEERING - FINAL LMAKUS Approved
09/13/2002 FIRE - FINAL LTHOMAS Approved
09/13/2002 FIRE SPKLR - FINAL LTHOMAS Approved
09/13/2002 PLUMBING - FINAL TRINIVJR Approved
09/13/2002 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved 1.) PLBG. FINAL IS OK 2.) NOTE: GAS INSPECTION UP TO BOILER IS OK SATE INSPECTOR HAS REQUIRED TO OWNER THAT THE BOILER BE ENERGIZED PRIOR TO HIS INSPECTION. SUBJECT TO THIS REQUEST UTILITY CLEARANCE CARD HAS BEEN RELEASED.
09/13/2002 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved IVRS - Inspection 0000*
09/13/2002 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection 0000*
09/13/2002 ROOF NAILING AQUIROZ Approved IVRS - Inspection 0000*
09/13/2002 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection 0000*
09/13/2002 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection 0000*
09/16/2002 PERMIT FINALED JYBARRA Approved
09/16/2002 RIGHT OF WAY - FINAL PWHIDDON Approved
09/16/2002 SIGN - FINAL JYBARRA Approved
09/17/2002 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection 0000*OK C OF O.
09/17/2002 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection 0000*OK C OF O.

Documents

File Name Document Type  
None DOCUMENTS VIEW
C OF O_10-22-2002.TIF CERT OF OCC VIEW
C OF O_09-19-2002.TIF CERT OF OCC VIEW