Permit: T02CM02367
Permit Details
Apply Date:
05/10/2002
Applicant:
BEN VOGEL
Description:
SFR:TD#15-44-93
Contractors:
- A R C I L L C ,
Permit Reviews
Permit Number - T02CM02367
Permit Status: C of o
Permit Description: SFR:TD#15-44-93
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/10/2002 | RESIDENTIAL BLDG/ZONING/FLOOD | 05/10/2002 | COMPLETED |
| 07/26/2002 | REVISION | 07/26/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02367
Permit Status: C of o
Permit Description: SFR:TD#15-44-93
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/10/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM02367
Permit Description: SFR:TD#15-44-93
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/06/2002 | EXCAVATION/LAYOUT REBAR & ZON | EDURAZO | Approved | IVRS - Inspection 0000* |
| 06/13/2002 | PLUMBING - ROUGH, SOIL | HPEDROZA | Approved | IVRS - Inspection 0000* |
| 06/17/2002 | ELECTRIC - UFER | JRIVA | Approved | IVRS - Inspection 0000* |
| 06/17/2002 | BUILDING PRE-SLAB | JRIVA | Approved | IVRS - Inspection 0000* |
| 07/05/2002 | EXT METAL CLIPS/EXT SHEATHING | JRIVA | Approved | IVRS - Inspection 0145*/ 1) PLAN CALLS FOR TJI AT 16" ON CENTER IN GARAGE. OVERSPAN IN TWO BAYS 2) PLAN CALLS FOR 4 X 6 POSTS EACH END OF GLB'S 3) BLOCK BEAMS TO PREVENT ROTATION 4) PORCH NOT READY 5) ENTRY NOT CLIPPED 6) CLIP ALL KING STUDS AND CORNERS 7) WEST BRACED PANEL NOT NAILED-SHINERS 8) CLIP ALL STUDS ON BEARING WALLS AND NON BEARING WALLS 9) ROOF NAIL HEADS AND STAPLE CROWNS TO HIGH. DRIVE FLUSH |
| 07/10/2002 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection 0000*/ 1) HOUSE OK-NOT PORCH |
| 07/19/2002 | MECHANICAL - INTERMEDIATE | FGREER | Approved | IVRS - Inspection 0000* |
| 07/19/2002 | PLUMBING - INTERMEDIATE | FGREER | Approved | IVRS - Inspection 0000* |
| 07/19/2002 | ELECTRIC - INTERMEDIATE | FGREER | Approved | IVRS - Inspection 0000* |
| 07/22/2002 | FRAMING | JRIVA | Approved | IVRS - Inspection 0000* |
| 07/30/2002 | SHEET ROCK NAILING | EDURAZO | Approved | IVRS - Inspection 0000* |
| 07/31/2002 | U VALUE FOR WINDOW | DBRITO | Approved | IVRS - Inspection 0000* |
| 07/31/2002 | STUCCO MESH | DBRITO | Approved | IVRS - Inspection 0000* |
| 08/23/2002 | PLUMBING - SEWER HCS CONNECT | JRIVA | Approved | IVRS - Inspection 0000* |
| 08/27/2002 | ELECTRIC - TEMPORARY SERVICE | JRIVA | Approved | IVRS - Inspection 0000* |
| 08/27/2002 | ELECTRIC - CABLE DROP | JRIVA | Approved | IVRS - Inspection 0000* |
| 08/30/2002 | PLUMBING - YARD WTR LINE/TEST | DQUINN | Approved | IVRS - Inspection 0000* |
| 10/22/2002 | PERMIT FINALED | JRIVA | Approved | |
| 10/22/2002 | MECHANICAL - FINAL | JRIVA | Approved | IVRS - Inspection 0000* |
| 10/22/2002 | PLUMBING - FINAL | JRIVA | Approved | IVRS - Inspection 0000* |
| 10/22/2002 | ELECTRIC - FINAL | JRIVA | Approved | IVRS - Inspection 0000* |
| 10/22/2002 | BUILDING - FINAL | JRIVA | Approved | IVRS - Inspection 0000* |