Permit: T02CM02248
Permit Details
Apply Date:
05/03/2002
Applicant:
SHELDON GENEVA E
Description:
ADDITION:FAMILY ROOM, BEDROOM,BATH & PORCH AT REAR
Permit Reviews
Permit Number - T02CM02248
Permit Status: Final
Permit Description: ADDITION:FAMILY ROOM, BEDROOM,BATH & PORCH AT REAR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/03/2002 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 05/21/2002 | COMPLETED |
| 05/29/2002 | REVISION | 05/29/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02248
Permit Status: Final
Permit Description: ADDITION:FAMILY ROOM, BEDROOM,BATH & PORCH AT REAR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/03/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02CM02248
Permit Description: ADDITION:FAMILY ROOM, BEDROOM,BATH & PORCH AT REAR
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/04/2002 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) SAN-TEE USE ONLY IN VERTICAL FOR DRAINAGE FITTINGS, SAN T AT SEWER CONNECT CHANGE TO COMBO 2) TUB VENT AS IS CAN'T BE USED AS A DRAIN OR (WET VENT) WITH SAN TEE LYING FLAT 4) NO WHERE TO DRAIN KITCHEN SINK 2" MINIMUM DRAIN LINE 5) ISOLATE REBAR THAT GOES IN GROUND FROM HORIZONTAL BARS 6) NEED VERTS AT EACH SIDE OF DOORS AND WINDOW |
| 06/11/2002 | REINFORCED MASONRY PRE-GROUT | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) WALL TOPPED OUT |
| 06/19/2002 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 08/06/2002 | MECHANICAL - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 08/06/2002 | PLUMBING - GAS PRESSURE TEST | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 08/06/2002 | PLUMBING - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 08/06/2002 | ELECTRIC - INTERMEDIATE | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 08/06/2002 | FRAMING | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 09/20/2002 | SHEET ROCK NAILING | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 12/03/2002 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | |
| 12/06/2002 | PERMIT FINALED | DQUINN | Approved | |
| 12/06/2002 | MECHANICAL - FINAL | DQUINN | Approved | IVRS - Inspection 0000* |
| 12/06/2002 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection 0000* |
| 12/06/2002 | ELECTRIC - FINAL | DQUINN | Approved | IVRS - Inspection 0000* |
| 12/06/2002 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection 0000* |
| 12/06/2002 | U VALUE FOR WINDOW | DQUINN | Approved |