Permit: T02CM02152
Permit Details
Apply Date:
04/29/2002
Applicant:
M R C CONSTRUCTION AND ELECTRICAL L L C
Description:
TI:PAY DAY LOANS
Contractors:
- M R C CONSTRUCTION AND ELECTRICAL L L C
Permit Reviews
Permit Number - T02CM02152
Permit Status: C of o
Permit Description: TI:PAY DAY LOANS
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/29/2002 | COMMERCIAL TI | 05/10/2002 | COMPLETED |
05/10/2002 | RESUBMITTAL | 05/10/2002 | COMPLETED |
05/23/2002 | REVISION | 05/23/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02152
Permit Status: C of o
Permit Description: TI:PAY DAY LOANS
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/29/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM02152
Permit Description: TI:PAY DAY LOANS
Total Completed Inspections - 19
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/24/2002 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection 0000*REVISED PLAN ON JOB UNDERGROUND SOIL OK TO BACKFILL TEST OK PLEASE WRAP ABS IN CONCREST. |
06/05/2002 | PLUMBING - ABOVE CEILING | JSTANLEY | Approved | IVRS - Inspection 0000*PROVIDE HANGER AT 90 THROU ROOF. 1.) PROVIDE ACCESS TO WATER HAMMEL ARRESTER. 2. PLEASE SEE SEC 1003. 94 UPC. 2" TRAP ARM REQUIRED & 2" TRAP. |
06/05/2002 | FRAMING | AMATHIES | Approved | |
06/05/2002 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* |
06/06/2002 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000*OK WALLS PLEASE SEAL BOXES WITH DUCT TAPE FOR DUST IN GRAVEL WALLS. |
06/07/2002 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000* |
06/11/2002 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
07/03/2002 | PLUMBING - FINAL | FMCCLURE | Approved | IVRS - Inspection 0000* |
07/03/2002 | PLUMBING - PROGRESS | FMCCLURE | Approved | |
07/03/2002 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection 0000*1.) VERIFY CORD CONNECTION FOR INSTAL HOT ALSO WE HAVE A 20AMP GFI ON A 30 AMP CIRCUIT. |
07/05/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
07/10/2002 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection 0000*OK FINAL. |
07/11/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
07/12/2002 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
07/15/2002 | FIRE - FINAL | LTHOMAS | Approved | |
07/16/2002 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
07/16/2002 | SIGN - FINAL | JSONKIN | Approved | IVRS - Inspection 0000* |
07/16/2002 | ENGINEERING - FINAL | DROBERTS | Approved | |
07/17/2002 | PERMIT FINALED | DROBERTS | Approved |