Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T02CM02023
Permit Details
Apply Date:
04/18/2002
Applicant:
KENNEDY, STEPHEN JAMES
Description:
NEW LIBRARY 158' x 78' MASONRY W/ GLASS AND METAL WALLS, STEEL ROOF,STEEL BEAMS AND COLUMNS
Architects:
- KENNEDY, STEPHEN JAMES
Permit Reviews
Permit Number - T02CM02023
Permit Status: Withdrwn
Permit Description: NEW LIBRARY 158' x 78' MASONRY W/ GLASS AND METAL WALLS, STEEL ROOF,STEEL BEAMS AND COLUMNS
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/18/2002 | COMMERCIAL NEW | 07/16/2002 | COMPLETED |
04/18/2002 | SITE | 07/16/2002 | COMPLETED |
07/16/2002 | SITE | 08/30/2002 | COMPLETED |
07/16/2002 | COMMERCIAL NEW | 10/11/2002 | STOPPED |
08/30/2002 | RESUBMITTAL - SITE | 04/16/2003 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02023
Permit Status: Withdrwn
Permit Description: NEW LIBRARY 158' x 78' MASONRY W/ GLASS AND METAL WALLS, STEEL ROOF,STEEL BEAMS AND COLUMNS
Total Outstanding Activity Conditions - 13
Date | Name |
---|---|
04/18/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
09/13/2002 | SPECIAL INSPECTION FOR CONCRETE IS REQUIRED.. |
09/13/2002 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
09/13/2002 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
09/13/2002 | SPECIAL INSPECTION FOR STRUCTURAL WELDING IS REQUIRED. |
09/13/2002 | SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED. |
09/13/2002 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
09/13/2002 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
09/13/2002 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
09/13/2002 | SPECIAL INSPECTION FOR EXPANSION ANCHORS IS REQUIRED. |
09/13/2002 | SHOP DRAWINGS REQUIRED FOR METAL ROOF DECKING. |
09/13/2002 | SHOP DRAWINGS REQUIRED FOR METAL ROOFING. |
09/13/2002 | SPECIAL INSPECTION IS REQUIRED FOR SHOP WELDING PER U.A.C. SECTION 306. |
Outstanding Inspections
Permit Status: Withdrwn
Permit Number: T02CM02023
Permite Description: NEW LIBRARY 158' x 78' MASONRY W/ GLASS AND METAL WALLS, STEEL ROOF,STEEL BEAMS AND COLUMNS
Total Outstanding Inspections - 28
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
EXCAVATION/LAYOUT REBAR & ZON | N/A | Not Inspected | ||
STEM WALL/RETAINING WALL | N/A | Not Inspected | ||
BUILDING PRE-SLAB | N/A | Not Inspected | ||
REINFORCED MASONRY PRE-GROUT | N/A | Not Inspected | ||
EXT METAL CLIPS/EXT SHEATHING | N/A | Not Inspected | ||
ROOF NAILING | N/A | Not Inspected | ||
FRAMING | N/A | Not Inspected | ||
SHEET ROCK NAILING | N/A | Not Inspected | ||
BUILDING - FINAL | N/A | Not Inspected | ||
ELECTRIC - UFER | N/A | Not Inspected | ||
ELECTRIC - UNDERGROUND | N/A | Not Inspected | ||
ELECTRIC - INTERMEDIATE | N/A | Not Inspected | ||
ELECTRIC - ABOVE CEILING | N/A | Not Inspected | ||
ELECTRIC - TEMPORARY SERVICE | N/A | Not Inspected | ||
ELECTRIC - CONSTRUCTION POWER | N/A | Not Inspected | ||
ELECTRIC - FINAL | N/A | Not Inspected | ||
OUTDOOR LIGHTING FINAL | N/A | Not Inspected | ||
PLUMBING - ROUGH, SOIL | N/A | Not Inspected | ||
PLUMBING - INTERMEDIATE | N/A | Not Inspected | ||
PLUMBING - ABOVE CEILING | N/A | Not Inspected | ||
PLUMBING - YARD WTR LINE/TEST | N/A | Not Inspected | ||
PLUMBING - GAS PRESSURE TEST | N/A | Not Inspected | ||
PLUMBING - SEWER HCS CONNECT | N/A | Not Inspected | ||
PLUMBING - PROGRESS | N/A | Not Inspected | ||
PLUMBING - FINAL | N/A | Not Inspected | ||
MECHANICAL - INTERMEDIATE | N/A | Not Inspected | ||
MECHANICAL - FINAL | N/A | Not Inspected | ||
LANDSCAPE - FINAL | N/A | Not Inspected |