Permit: T02CM01777
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
9218 E DESERT COVE CI
Address NEW:
9218 E DESERT COVE CI
Apply Date:
04/08/2002
Applicant:
GENESEE COMPANY *P
Description:
SFR:TD#15-28-07 T02VL00636
Contractors:
- GENESEE COMPANY *P
Permit Reviews
Permit Number - T02CM01777
Permit Status: C of o
Permit Description: SFR:TD#15-28-07 T02VL00636
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/08/2002 | RESIDENTIAL BLDG/ZONING/FLOOD | 04/09/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM01777
Permit Status: C of o
Permit Description: SFR:TD#15-28-07 T02VL00636
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/08/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM01777
Permit Description: SFR:TD#15-28-07 T02VL00636
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/03/2002 | PLUMBING - SEWER HCS CONNECT | HLEYVA | Approved | IVRS - Inspection 0000* |
| 05/03/2002 | PLUMBING - YARD WTR LINE/TEST | HLEYVA | Approved | IVRS - Inspection 0000* |
| 05/03/2002 | PLUMBING - ROUGH, SOIL | HLEYVA | Approved | IVRS - Inspection 0000*/ 1) NOTE WILL NEED BWV ACCESS AT FINAL |
| 05/09/2002 | ELECTRIC - UFER | HLEYVA | Approved | IVRS - Inspection 0000* |
| 05/09/2002 | BUILDING PRE-SLAB | HLEYVA | Approved | IVRS - Inspection 0000* |
| 05/09/2002 | EXCAVATION/LAYOUT REBAR & ZON | HLEYVA | Approved | IVRS - Inspection 0000* |
| 05/20/2002 | ELECTRIC - TEMPORARY SERVICE | HLEYVA | Approved | IVRS - Inspection 0000* |
| 05/20/2002 | ELECTRIC - CABLE DROP | HLEYVA | Approved | IVRS - Inspection 0000* |
| 06/04/2002 | ROOF NAILING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 06/05/2002 | EXT METAL CLIPS/EXT SHEATHING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 06/10/2002 | MECHANICAL - INTERMEDIATE | HLEYVA | Approved | IVRS - Inspection 0000* |
| 06/10/2002 | PLUMBING - GAS PRESSURE TEST | HLEYVA | Approved | IVRS - Inspection 0000* |
| 06/10/2002 | PLUMBING - INTERMEDIATE | HLEYVA | Approved | IVRS - Inspection 0000* |
| 06/10/2002 | ELECTRIC - INTERMEDIATE | HLEYVA | Approved | IVRS - Inspection 0000* |
| 06/10/2002 | FRAMING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 06/24/2002 | SHEET ROCK NAILING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 06/24/2002 | STUCCO MESH | HLEYVA | Approved | IVRS - Inspection 0000* |
| 07/26/2002 | PERMIT FINALED | HLEYVA | Approved | |
| 07/26/2002 | MECHANICAL - FINAL | HLEYVA | Approved | IVRS - Inspection 0000* |
| 07/26/2002 | PLUMBING - FINAL | HLEYVA | Approved | IVRS - Inspection 0000* |
| 07/26/2002 | ELECTRIC - FINAL | HLEYVA | Approved | IVRS - Inspection 0000* |
| 07/26/2002 | BUILDING - FINAL | HLEYVA | Approved | IVRS - Inspection 0000* |