Permit: T02CM01527
Permit Details
Apply Date:
03/21/2002
Applicant:
CONSTRUCTION DOCUMENT SERVICES
Description:
SFR
Contractors:
- HICKEY CONSTRUCTION
Permit Reviews
Permit Number - T02CM01527
Permit Status: Expired
Permit Description: SFR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/21/2002 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 04/25/2002 | COMPLETED |
| 04/30/2002 | RESUBMITTAL | 05/13/2002 | COMPLETED |
| 05/24/2002 | REVISION | 06/25/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM01527
Permit Status: Expired
Permit Description: SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 03/21/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T02CM01527
Permite Description: SFR
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| PLUMBING - YARD WTR LINE/TEST | N/A | Not Inspected | ||
| PLUMBING - GAS PRESS TEST FNL | N/A | Not Inspected | ||
| PLUMBING - SEWER HCS CONNECT | N/A | Not Inspected | ||
| 11/21/2002 | BUILDING - FINAL | N/A | Partial Approval | IVRS - Inspection 0000*/ 1) SEAL A/C LINES EXTERIOR WALL 2) NEED ACCESS INTO UTILITY WATER HEATER FURNACE ROOMS 3) GAS SHUT OFF TO BE OUTSIDE FIREPLACE 4) OPEN BULBS CLOSET ? 5) INSULATION STUCCO CERTS 6) 3055 SEWER ? AND 3040 SITE WATER VERIFY INSPECTION APPROVAL 7) COMPLETE ELECTRIC 8) COMPLETE PLUMBING IN BATH |
| 11/21/2002 | ELECTRIC - FINAL | N/A | Partial Approval | IVRS - Inspection 0000* |
| 11/21/2002 | PLUMBING - FINAL | N/A | Partial Approval | IVRS - Inspection 0000* |
| 11/21/2002 | MECHANICAL - FINAL | N/A | Partial Approval | IVRS - Inspection 0000* |
Completed Inspections
Permit Status: Expired
Permit Number: T02CM01527
Permit Description: SFR
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/11/2002 | PLUMBING - ROUGH, SOIL | ROHAVER | Approved | IVRS - Inspection 0000* |
| 06/27/2002 | BUILDING PRE-SLAB | ROHAVER | Approved | IVRS - Inspection 0000* |
| 06/27/2002 | EXCAVATION/LAYOUT REBAR & ZON | ROHAVER | Approved | IVRS - Inspection 0000* |
| 08/20/2002 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection 0000* |
| 08/20/2002 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) ROOF FRAMING PLAN CALLS FOR PARTICULAR COLUMN SIZES UNDER CERTAIN HEADERS AND BEAMS (SEE SUPPORT FOR GIRDER EAST WALL) 2) PLAN CALLS FOR 2 X 10 ROOF RAFTERS AT PORCH 2 X 8 WILL WORK 24" ON CENTER=13'-8" SPAN IS 12'-4" CHECK WITH CONTRACTOR 3) LEAVE COMPLETE SET OF TRUSS DRAWINGS INCLUDING REPAIRS AND ALTERATIONS 4) OK ROOF DECK AND WALLS |
| 09/03/2002 | MECHANICAL - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection 0000* |
| 09/03/2002 | PLUMBING - GAS PRESSURE TEST | ROHAVER | Approved | IVRS - Inspection 0000* |
| 09/03/2002 | PLUMBING - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection 0000* |
| 09/03/2002 | ELECTRIC - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection 0000* |
| 09/03/2002 | FRAMING | ROHAVER | Approved | IVRS - Inspection 0000*/ 1) RE-INSPECTION |
| 09/10/2002 | SHEET ROCK NAILING | ROHAVER | Approved | IVRS - Inspection 0000* |
| 09/19/2002 | STUCCO MESH | ROHAVER | Approved | IVRS - Inspection 0000* |