Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY NEW
Address NEW:
2449 N WINDING PL
Apply Date:
03/21/2002
Applicant:
CONSTRUCTION DOCUMENT SERVICES
Description:
SFR
Contractors:
  • HICKEY CONSTRUCTION

Permit Reviews

Permit Number - T02CM01527
Permit Status: Expired
Permit Description: SFR
Start Date Submittal Complete Date Status  
03/21/2002 RESIDENTIAL BLDG/ZONING/FLOOD/WWM 04/25/2002 COMPLETED Review Details
04/30/2002 RESUBMITTAL 05/13/2002 COMPLETED Review Details
05/24/2002 REVISION 06/25/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM01527
Permit Status: Expired
Permit Description: SFR
Total Outstanding Activity Conditions - 1
Date Name
03/21/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T02CM01527
Permite Description: SFR
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
PLUMBING - YARD WTR LINE/TEST N/A Not Inspected
PLUMBING - GAS PRESS TEST FNL N/A Not Inspected
PLUMBING - SEWER HCS CONNECT N/A Not Inspected
11/21/2002 BUILDING - FINAL N/A Partial Approval IVRS - Inspection 0000*/ 1) SEAL A/C LINES EXTERIOR WALL 2) NEED ACCESS INTO UTILITY WATER HEATER FURNACE ROOMS 3) GAS SHUT OFF TO BE OUTSIDE FIREPLACE 4) OPEN BULBS CLOSET ? 5) INSULATION STUCCO CERTS 6) 3055 SEWER ? AND 3040 SITE WATER VERIFY INSPECTION APPROVAL 7) COMPLETE ELECTRIC 8) COMPLETE PLUMBING IN BATH
11/21/2002 ELECTRIC - FINAL N/A Partial Approval IVRS - Inspection 0000*
11/21/2002 PLUMBING - FINAL N/A Partial Approval IVRS - Inspection 0000*
11/21/2002 MECHANICAL - FINAL N/A Partial Approval IVRS - Inspection 0000*

Completed Inspections

Permit Status: Expired
Permit Number: T02CM01527
Permit Description: SFR
Total Completed Inspections - 12
Date Description Inspector Results Comments
06/11/2002 PLUMBING - ROUGH, SOIL ROHAVER Approved IVRS - Inspection 0000*
06/27/2002 BUILDING PRE-SLAB ROHAVER Approved IVRS - Inspection 0000*
06/27/2002 EXCAVATION/LAYOUT REBAR & ZON ROHAVER Approved IVRS - Inspection 0000*
08/20/2002 ROOF NAILING RFREIDIN Approved IVRS - Inspection 0000*
08/20/2002 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*/ 1) ROOF FRAMING PLAN CALLS FOR PARTICULAR COLUMN SIZES UNDER CERTAIN HEADERS AND BEAMS (SEE SUPPORT FOR GIRDER EAST WALL) 2) PLAN CALLS FOR 2 X 10 ROOF RAFTERS AT PORCH 2 X 8 WILL WORK 24" ON CENTER=13'-8" SPAN IS 12'-4" CHECK WITH CONTRACTOR 3) LEAVE COMPLETE SET OF TRUSS DRAWINGS INCLUDING REPAIRS AND ALTERATIONS 4) OK ROOF DECK AND WALLS
09/03/2002 MECHANICAL - INTERMEDIATE ROHAVER Approved IVRS - Inspection 0000*
09/03/2002 PLUMBING - GAS PRESSURE TEST ROHAVER Approved IVRS - Inspection 0000*
09/03/2002 PLUMBING - INTERMEDIATE ROHAVER Approved IVRS - Inspection 0000*
09/03/2002 ELECTRIC - INTERMEDIATE ROHAVER Approved IVRS - Inspection 0000*
09/03/2002 FRAMING ROHAVER Approved IVRS - Inspection 0000*/ 1) RE-INSPECTION
09/10/2002 SHEET ROCK NAILING ROHAVER Approved IVRS - Inspection 0000*
09/19/2002 STUCCO MESH ROHAVER Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
None DOCUMENTS VIEW