Permit: T02CM01387
Permit Details
Status:
Final
Type:
SINGLE FAMILY NEW
Address:
10125 E PLACITA DEL TIMBRE
Address NEW:
10125 E PLACITA DEL TIMBRE
Apply Date:
03/13/2002
Applicant:
RICHMOND AMERICAN HOMES
Description:
SFR:TD#15-15-24
Contractors:
- RICHMOND AMERICAN HOMES ''T''
Permit Reviews
Permit Number - T02CM01387
Permit Status: Final
Permit Description: SFR:TD#15-15-24
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/13/2002 | RESIDENTIAL BLDG/ZONING/FLOOD | 04/02/2002 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T02CM01387
Permit Description: SFR:TD#15-15-24
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/03/2002 | PLUMBING - SEWER HCS CONNECT | DQUINN | Approved | IVRS - Inspection 0000* |
| 04/03/2002 | PLUMBING - YARD WTR LINE/TEST | DQUINN | Approved | IVRS - Inspection 0000* |
| 04/03/2002 | PLUMBING - ROUGH, SOIL | DQUINN | Approved | IVRS - Inspection 0000* |
| 04/24/2002 | ROOF NAILING | DQUINN | Approved | IVRS - Inspection 0999* |
| 04/24/2002 | EXT METAL CLIPS/EXT SHEATHING | DQUINN | Approved | IVRS - Inspection 0999*/ 1) A FEW ROWS NOT NAILED ON EAST ROOF PLANE. NAIL WEST BIRD BOARDS 2) INSTALL ALTERNATE H.D. AT REAR WINDOW 3) STRAP ALL CUT BOTTOM PLATES AND REPAIR SLAB BLOWOUT AT REAR BATH |
| 04/29/2002 | ELECTRIC - TEMPORARY SERVICE | DQUINN | Approved | IVRS - Inspection 0000* |
| 04/29/2002 | ELECTRIC - CABLE DROP | DQUINN | Approved | IVRS - Inspection 0000* |
| 05/02/2002 | MECHANICAL - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection 0000* |
| 05/02/2002 | MECHANICAL - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection 0999* |
| 05/02/2002 | PLUMBING - GAS PRESSURE TEST | DQUINN | Approved | IVRS - Inspection 0000* |
| 05/02/2002 | PLUMBING - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection 0000* |
| 05/02/2002 | PLUMBING - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection 0999*/ 1) BLOCK COMBUSTION/RELIEF STUD BAY 2) FHA TOP PLATES AT GAS MAIN 3) SHIM HEADERS WHERE NEEDED 4) MOVE PEX FROM K IS CAN LIGHT AND MASTER SHOWER LIGHT 5) BLOCK OUT 4 GANG IN DINING AREA |
| 05/02/2002 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection 0000* |
| 05/02/2002 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection 0999* |
| 05/02/2002 | FRAMING | DQUINN | Approved | IVRS - Inspection 0000* |
| 05/02/2002 | FRAMING | DQUINN | Approved | IVRS - Inspection 0999* |
| 05/10/2002 | SHEET ROCK NAILING | DQUINN | Approved | IVRS - Inspection 0000* |
| 05/10/2002 | U VALUE FOR WINDOW | DQUINN | Approved | IVRS - Inspection 0000* |
| 05/10/2002 | STUCCO MESH | DQUINN | Approved | IVRS - Inspection 0000* |
| 06/07/2002 | PERMIT FINALED | DQUINN | Approved | |
| 06/07/2002 | MECHANICAL - FINAL | DQUINN | Approved | IVRS - Inspection 0000* |
| 06/07/2002 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection 0000* |
| 06/07/2002 | ELECTRIC - FINAL | DQUINN | Approved | IVRS - Inspection 0000* |
| 06/07/2002 | ELECTRIC - UNDERGROUND | DQUINN | Approved | IVRS - Inspection 0000* |
| 06/07/2002 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection 0000* |