Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
323 N PLUMER AV
Address NEW:
323 N PLUMER AV
Apply Date:
03/04/2002
Applicant:
GRYGUTIS, JAMES EDWARD
Description:
ADDITION:GARAGE
Contractors:
  • CLOSETSCAPES ,

Permit Reviews

Permit Number - T02CM01220
Permit Status: Final
Permit Description: ADDITION:GARAGE
Start Date Submittal Complete Date Status  
03/04/2002 RESIDENTIAL BLDG/ZONING/FLOOD 03/05/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM01220
Permit Status: Final
Permit Description: ADDITION:GARAGE
Total Outstanding Activity Conditions - 1
Date Name
03/04/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T02CM01220
Permit Description: ADDITION:GARAGE
Total Completed Inspections - 10
Date Description Inspector Results Comments
03/29/2002 BUILDING PRE-SLAB JRIVA Approved IVRS - Inspection 0000*
03/29/2002 EXCAVATION/LAYOUT REBAR & ZON JRIVA Approved IVRS - Inspection 0000*
04/08/2002 REINFORCED MASONRY PRE-GROUT JRIVA Approved IVRS - Inspection 0000*/ 1) 4TH LIFT OK TO GROUT. CALL FOR BOND BEAM INSPECTION
04/21/2002 FRAMING DBRITO Approved IVRS - Inspection 0000*
04/22/2002 ROOF NAILING RFREIDIN Approved IVRS - Inspection 0000*
04/22/2002 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*
06/06/2002 PERMIT FINALED MTESTER Approved
06/06/2002 ELECTRIC - FINAL MTESTER Approved IVRS - Inspection 0000*
06/06/2002 ELECTRIC - INTERMEDIATE MTESTER Approved IVRS - Inspection 0000*
06/06/2002 BUILDING - FINAL MTESTER Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
T02CM01220 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW