Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T02CM01185
Permit Details
Apply Date:
03/01/2002
Applicant:
K B HOME OF TUCSON ****''T''
Description:
SFR:TD#15-21-18
Contractors:
- K B HOME OF TUCSON ****''T''
Permit Reviews
Permit Number - T02CM01185
Permit Status: Final
Permit Description: SFR:TD#15-21-18
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/01/2002 | RESIDENTIAL BLDG/ZONING/FLOOD | 03/04/2002 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T02CM01185
Permit Description: SFR:TD#15-21-18
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/15/2002 | PLUMBING - YARD WTR LINE/TEST | FGREER | Approved | IVRS - Inspection 0000* |
03/15/2002 | PLUMBING - ROUGH, SOIL | FGREER | Approved | IVRS - Inspection 0000* |
03/19/2002 | PLUMBING - SEWER HCS CONNECT | FGREER | Approved | IVRS - Inspection 0000* |
03/21/2002 | ELECTRIC - UFER | DQUINN | Approved | IVRS - Inspection 0000* |
03/21/2002 | BUILDING PRE-SLAB | DQUINN | Approved | IVRS - Inspection 0000* |
04/08/2002 | EXT METAL CLIPS/EXT SHEATHING | MTESTER | Approved | IVRS - Inspection 0000* |
04/09/2002 | ROOF NAILING | MTESTER | Approved | IVRS - Inspection 0000* |
04/15/2002 | PLUMBING - INTERMEDIATE | FGREER | Approved | IVRS - Inspection 0999* |
04/15/2002 | ELECTRIC - TEMPORARY SERVICE | FGREER | Approved | IVRS - Inspection 0000* |
04/15/2002 | ELECTRIC - CABLE DROP | FGREER | Approved | IVRS - Inspection 0000* |
04/15/2002 | FRAMING | FGREER | Approved | IVRS - Inspection 0999*/ 1) MISSING DETAIL SD4/19 AT GARAGE DOOR 2) CLEANOUT MISSING AT MASTER BATH |
04/19/2002 | STUCCO MESH | EDURAZO | Approved | IVRS - Inspection 0000* |
04/22/2002 | SHEET ROCK NAILING | FGREER | Approved | IVRS - Inspection 0000* |
05/29/2002 | PERMIT FINALED | HPEDROZA | Approved | |
05/29/2002 | MECHANICAL - FINAL | HPEDROZA | Approved | IVRS - Inspection 0000* |
05/29/2002 | MECHANICAL - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection 0000* |
05/29/2002 | PLUMBING - FINAL | HPEDROZA | Approved | IVRS - Inspection 0000* |
05/29/2002 | ELECTRIC - FINAL | HPEDROZA | Approved | IVRS - Inspection 0000* |
05/29/2002 | ELECTRIC - INTERMEDIATE | HPEDROZA | Approved | IVRS - Inspection 0000* |
05/29/2002 | BUILDING - FINAL | HPEDROZA | Approved | IVRS - Inspection 0000* |
05/29/2002 | U VALUE FOR WINDOW | HPEDROZA | Approved | IVRS - Inspection 0000* |