Permit: T02CM00931
Permit Details
Apply Date:
02/15/2002
Applicant:
JAMES HOCKINGS
Description:
SHELL FACTORY BUILDING 130' x 77'4" BUILDING, MASONRY W/ STEEL COLUMNS, BEAMS, AND ROOF DECK,PORCH W/ CONCRETE COLUMNS, WOOD ROOF BEAMS, JOISTS AND SHEATHING
Contractors:
- 8 A BUILDERS
Permit Reviews
Permit Number - T02CM00931
Permit Status: Final
Permit Description: SHELL FACTORY BUILDING 130' x 77'4" BUILDING, MASONRY W/ STEEL COLUMNS, BEAMS, AND ROOF DECK,PORCH W/ CONCRETE COLUMNS, WOOD ROOF BEAMS, JOISTS AND SHEATHING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/15/2002 | COMMERCIAL NEW | 04/03/2002 | COMPLETED |
| 04/17/2002 | RESUBMITTAL | 04/26/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM00931
Permit Status: Final
Permit Description: SHELL FACTORY BUILDING 130' x 77'4" BUILDING, MASONRY W/ STEEL COLUMNS, BEAMS, AND ROOF DECK,PORCH W/ CONCRETE COLUMNS, WOOD ROOF BEAMS, JOISTS AND SHEATHING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 02/15/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02CM00931
Permit Description: SHELL FACTORY BUILDING 130' x 77'4" BUILDING, MASONRY W/ STEEL COLUMNS, BEAMS, AND ROOF DECK,PORCH W/ CONCRETE COLUMNS, WOOD ROOF BEAMS, JOISTS AND SHEATHING
Total Completed Inspections - 18
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/03/2002 | ELECTRIC - TEMPORARY POLE | JORTA | Approved | IVRS - Inspection 0000* 4/0 CU UFER ATTACHED TO REBAR |
| 05/03/2002 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000* |
| 05/13/2002 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection 0000* |
| 05/15/2002 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | 1.) SOIL WATER TEST IS OK 2.) HCS SEWER MAIN TAP IS OK 3.) OK TO BACKFILL TRENCH. |
| 05/16/2002 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* |
| 06/06/2002 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | IVRS - Inspection 0000* |
| 08/05/2002 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection 0000*PROGRESS APPROVED. |
| 08/28/2002 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
| 08/28/2002 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 08/28/2002 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
| 08/29/2002 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000*SHELL APPROVED. |
| 08/29/2002 | ELECTRIC - UNDERGROUND | JORTA | Approved | |
| 08/30/2002 | FIRE - FINAL | LTHOMAS | Approved | |
| 09/03/2002 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*1.) PLUMBING FINAL OK OK PENDING VERIFICATION OF CERTIFICATION OF RPPBP. WATTS 2" 009 # 190628. IN OTHER WORDS, TAKE A COPY OF CERTIFICATION DOWNTOWN WITH YOU WHEN YOU GO TO PICK UP C OF O. 2.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS. |
| 09/03/2002 | OUTDOOR LIGHTING FINAL | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 09/03/2002 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 09/04/2002 | PERMIT FINALED | LHANLY | Approved | |
| 09/04/2002 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000*OK TEMP POWER FOR TI. 2.) SPECIAL INSPECTION REPORTS REVIEWED & FINAL COMPLIANCE REPORT ACCEPTED ATTACHED. |