Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T02CM00352
Permit Details
Apply Date:
01/23/2002
Applicant:
RICHMOND AMERICAN HOMES
Description:
SFR:TD#15-15-24
Contractors:
- RICHMOND AMERICAN HOMES ''T''
Permit Reviews
Permit Number - T02CM00352
Permit Status: Final
Permit Description: SFR:TD#15-15-24
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/23/2002 | RESIDENTIAL BLDG/ZONING/FLOOD | 01/28/2002 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T02CM00352
Permit Description: SFR:TD#15-15-24
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/14/2002 | PLUMBING - SEWER HCS CONNECT | BSTEVENS | Approved | IVRS - Inspection 0000* |
02/14/2002 | PLUMBING - YARD WTR LINE/TEST | BSTEVENS | Approved | IVRS - Inspection 0000* |
02/14/2002 | PLUMBING - ROUGH, SOIL | BSTEVENS | Approved | IVRS - Inspection 0000* |
02/15/2002 | ELECTRIC - UFER | BSTEVENS | Approved | IVRS - Inspection 0000* |
02/15/2002 | BUILDING PRE-SLAB | BSTEVENS | Approved | IVRS - Inspection 0000* |
02/15/2002 | STEM WALL/RETAINING WALL | BSTEVENS | Approved | IVRS - Inspection 0000* |
02/15/2002 | EXCAVATION/LAYOUT REBAR & ZON | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/01/2002 | ELECTRIC - TEMPORARY SERVICE | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/01/2002 | ELECTRIC - CABLE DROP | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/01/2002 | ROOF NAILING | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/05/2002 | EXT METAL CLIPS/EXT SHEATHING | BSTEVENS | Approved | IVRS - Inspection 0000* 1.) NEED ALTERNATE HOLD DOWN AT PATIO CORNER OVER SPAULLED. 2.) SHEARWALL INTERSECTIONS NEED PROPER NAILING. |
03/15/2002 | MECHANICAL - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/15/2002 | PLUMBING - GAS PRESSURE TEST | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/15/2002 | PLUMBING - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/15/2002 | ELECTRIC - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/15/2002 | FRAMING | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/25/2002 | SHEET ROCK NAILING | BSTEVENS | Approved | IVRS - Inspection 0000* |
03/25/2002 | U VALUE FOR WINDOW | BSTEVENS | Approved | IVRS - Inspection 0000* |
04/04/2002 | STUCCO MESH | DQUINN | Approved | IVRS - Inspection 0000* |
04/26/2002 | PERMIT FINALED | DQUINN | Approved | |
04/26/2002 | MECHANICAL - FINAL | DQUINN | Approved | IVRS - Inspection 0000* |
04/26/2002 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection 0000* |
04/26/2002 | ELECTRIC - FINAL | DQUINN | Approved | IVRS - Inspection 0000* |
04/26/2002 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection 0000* |