Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T02CM00311
Permit Details
Apply Date:
01/22/2002
Applicant:
LPL PROPERTIES OF CALIFORNIA LTD
Description:
INSTALL SERVICE DOOR IN MASONRY WALL OF RETAIL BUILDING 8' x 8'8" DOOR OPENING IN EXISTING CMU WALL, TUBE STEEL FOR JAMB REINFORCEMENT ANCHORED TO EACH JAMB AND STEEL LINTEL W/ 2-#4 BARS OVER OPENING.
Architects:
- CARHUFF, DIANE KREBS
Contractors:
- K J L AND ASSOCIATES INC DBA
Permit Reviews
Permit Number - T02CM00311
Permit Status: Final
Permit Description: INSTALL SERVICE DOOR IN MASONRY WALL OF RETAIL BUILDING 8' x 8'8" DOOR OPENING IN EXISTING CMU WALL, TUBE STEEL FOR JAMB REINFORCEMENT ANCHORED TO EACH JAMB AND STEEL LINTEL W/ 2-#4 BARS OVER OPENING.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/22/2002 | COMMERCIAL-BLDG/FIRE ONLY | 03/01/2002 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T02CM00311
Permit Description: INSTALL SERVICE DOOR IN MASONRY WALL OF RETAIL BUILDING 8' x 8'8" DOOR OPENING IN EXISTING CMU WALL, TUBE STEEL FOR JAMB REINFORCEMENT ANCHORED TO EACH JAMB AND STEEL LINTEL W/ 2-#4 BARS OVER OPENING.
Total Completed Inspections - 6
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/11/2002 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection 0000* |
02/11/2002 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
02/13/2002 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection 0000* |
02/27/2002 | PERMIT FINALED | LHANLY | Approved | |
02/27/2002 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000* |
02/27/2002 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |