Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Address NEW:
122 S OLSEN AV #110
Apply Date:
01/03/2002
Applicant:
INTERTECH ARCHITECTS
Description:
TI:OFFICE
Architects:
  • SWAN WAYNE E
Contractors:
  • L AND C CONSTRUCTION ,

Permit Reviews

Permit Number - T02CM00026
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
01/03/2002 COMMERCIAL TI 01/11/2002 COMPLETED Review Details
01/11/2002 RESUBMITTAL 01/11/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM00026
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
01/03/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T02CM00026
Permit Description: TI:OFFICE
Total Completed Inspections - 16
Date Description Inspector Results Comments
01/29/2002 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
02/01/2002 ELECTRIC - INTERMEDIATE MCAPISTR Approved IVRS - Inspection 0000*1.) NO SUB PANEL FEEDERS IN AT THIS TIME 2.) REMOVE THE PANEL NEUTRAL BAR TO CAN BONDING JUMPER. 3.) USE CRIMP SLEEVE TO SECURE TWISTED GROUNDING PIGTAILS AT 2 GANG SWITCH BOX.
05/02/2002 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection 0000*
05/02/2002 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000* 1.) CONNECTIONS TO EXISTING OK ABS AND COPPER OK. 2.) GAS PIPING OK PRESSURE TEST OK 3.) OK TO COVER.
05/16/2002 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection 0000*
05/16/2002 FRAMING LHANLY Approved IVRS - Inspection 0000*
08/23/2002 FIRE - FINAL LTHOMAS Approved OK FOR C OF O
08/23/2002 PLUMBING - FINAL FMCCLURE Approved IVRS - Inspection 0000*
08/23/2002 ELECTRIC - FINAL MCAPISTR Approved IVRS - Inspection 0000*
08/23/2002 BUILDING - FINAL LHANLY Approved IVRS - Inspection 0000*
08/26/2002 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
08/26/2002 PLUMBING - PROGRESS FMCCLURE Approved
09/11/2002 RIGHT OF WAY - FINAL LLOPEZ Approved
09/11/2002 SIGN - FINAL JYBARRA Approved IVRS - Inspection 0000*
09/11/2002 ENGINEERING - FINAL JBRUCKME Approved
09/12/2002 PERMIT FINALED LLOPEZ Approved