Permit Reviews

Permit Number - T02BU00583
Permit Status: Final
Permit Description: GRADING:460CY CUT & 950CY FILL
Start Date Submittal Complete Date Status  
02/21/2002 GRADING 05/08/2002 COMPLETED Review Details
05/08/2002 GRADING 09/26/2002 STOPPED Review Details
07/07/2003 OTHER 07/07/2003 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02BU00583
Permit Status: Final
Permit Description: GRADING:460CY CUT & 950CY FILL
Total Outstanding Activity Conditions - 1
Date Name
02/21/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T02BU00583
Permit Description: GRADING:460CY CUT & 950CY FILL
Total Completed Inspections - 3
Date Description Inspector Results Comments
05/28/2004 GRADING - FINAL DROBERTS Approved 1) BASIN OUTLET NOT PER THE APPROVED PLANS.
2) ROOF DRAINAGE OUTLET NOT VISABLE IN THE EAST DRAINAGEWAY.
3)ROCKRIP AT THE BASIN OUTLET, NOT SIZED PER THE APPROVED PLAN, 6-INCH, D=.50 IS NOTED ON THE PLANS.
4) ADDITIONAL ROCK RIPRAP AT THE ROOF DRAIN DOWN SPOUTS IS NEEDED
06/02/2004 LANDSCAPE INSPECTION ACONNOR Approved
06/02/2004 LANDSCAPE INSPECTION ACONNOR Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
PAGE1.TIF GRADING PLANS VIEW
PAGE2.TIF GRADING PLANS VIEW
PGS1-2.PDF GRADING PLANS VIEW