Permit: T01PL00935
Permit Details
Apply Date:
05/01/2001
Applicant:
AQUINO SONIA
Description:
WATER HEATER:REPLACEMENT
Permit Reviews
Permit Number - T01PL00935
Permit Status: Withdrwn
Permit Description: WATER HEATER:REPLACEMENT
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/01/2001 | PLUMBING | 05/01/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01PL00935
Permit Status: Withdrwn
Permit Description: WATER HEATER:REPLACEMENT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/01/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Withdrwn
Permit Number: T01PL00935
Permite Description: WATER HEATER:REPLACEMENT
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/16/2001 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection 0999* 1) NEED AN EXPANSION TANK INSTALLED ON THE COLD WATER SIDE. 2) NEED A SHUT OFF VALVE ON THE COLD WATER SIDE 3) THE RELEIF VALVE NEEDS PIPED TO THE OUTSIDE 4) THREE SEWS ARE REQUIRED ON EVERY JOINT ON THE FLUE PIPE |