Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
1202 N AVENIDA CASCADA
Apply Date:
01/23/2001
Applicant:
BETTER TASTING WATER
Description:
WATER:COND(APA)
Contractors:
  • BETTER TASTING WATER

Outstanding Activity Conditions

Permit Number - T01PL00209
Permit Status: Expired
Permit Description: WATER:COND(APA)
Total Outstanding Activity Conditions - 1
Date Name
01/23/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T01PL00209
Permite Description: WATER:COND(APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
04/25/2001 PLUMBING - FINAL N/A Denied IVRS - Inspection 0999* 1) TYPE M COPPER IS NOT APPROVED MATERIAL FOR WATER DISTRIBUTION UNDER GROUND 2) MUST INSOLATE ENTIRE EXPOSED COPPER LINES AND PROPERLY TAPE INSULATION(NEATLY) 3) DISHWASHER AIR GAP IS NOT APPROVED APPLICATION FOR THIS SYSTEM. STILL HAVE CROSS CONNECTION WITH DISCHARGE DRAIN LINE INTO VENT ON ROOF SEE SEC 202.0 94 UPC 4) MUST PAY RE INSP FEE BEFORE NEXT INSP.

Documents

File Name Document Type  
T01PL00209 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW