Permit: T01OT00210
Permit Details
Apply Date:
07/11/2001
Applicant:
SARAH LONG/MICHAEL BROWN
Description:
C OF O:THE ARBORS ADULT CARE HOME
Permit Reviews
Permit Number - T01OT00210
Permit Status: C of o
Permit Description: C OF O:THE ARBORS ADULT CARE HOME
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/11/2001 | C OF O | 07/11/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T01OT00210
Permit Description: C OF O:THE ARBORS ADULT CARE HOME
Total Completed Inspections - 5
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/25/2001 | ELECTRIC - FINAL | DSANTACR | Approved | 1. SMOKE DETECTORS IN HALLWAY UP AND DOWN STAIRS ARE INTER CONNECTED. BUT NOT BEDROOMS EAT OPERATED. 2.) EMERGENCY LIGHTING REQUIRED UPSTAIRS AND DOWNSTAIRS HALLWAYS AND EXIT AREAS. 3.0 GFCI RECEPTACLES REQUIRED IN BATHROOM BY SINKS AND BY KITCHEN SINK 4.)OUTSIDE RECEPTACLES TO BE GFCI PROTECTED. |
| 08/01/2001 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O CONFIRMED SAFE OPERATION OF FURANCE. |
| 08/01/2001 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) PLBG FINAL IS OK . |
| 08/08/2001 | BUILDING - FINAL | AMATHIES | Approved | |
| 08/14/2001 | PERMIT FINALED | JMILITEL | Approved |