Permit: T01ME01039
Permit Details
Apply Date:
12/12/2001
Applicant:
D AND H AIR CONDITIONING CO,*C
Description:
A/C & FURNACE:REPLACE
Contractors:
- D AND H AIR CONDITIONING CO,*C
Outstanding Activity Conditions
Permit Number - T01ME01039
Permit Status: Expired
Permit Description: A/C & FURNACE:REPLACE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/12/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T01ME01039
Permite Description: A/C & FURNACE:REPLACE
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/12/2002 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection 0999*YOU CANNOT INCREASE THE SIZE OF THE GAS LINE 1/2" TO 3/4. CHECK YOUR SIZING CHART FOR 1/2" PIPE TO 100,000 BTU 75' FROM THE METER. PROVIDE A PRESSURE TEST ON NEW GAS PIPING. RECALL FOR FINAL INSPECTION. |