Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Address:
3650 E LEE ST
Address NEW:
3650 E LEE ST
Apply Date:
04/23/2001
Applicant:
BOSS CONSTRUCTION INC. *T
Description:
INSTALL:FURNACE & A/C SYSTEM (APA)
Contractors:
  • BOSS CONSTRUCTION INC. *T

Outstanding Activity Conditions

Permit Number - T01ME00347
Permit Status: Closed
Permit Description: INSTALL:FURNACE & A/C SYSTEM (APA)
Total Outstanding Activity Conditions - 1
Date Name
04/23/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T01ME00347
Permite Description: INSTALL:FURNACE & A/C SYSTEM (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
05/31/2001 MECHANICAL - FINAL N/A Denied 1)USE A FLASHING WHERE CONDENSATE DRAIN PENETRATES THE ROOF.2)MARK THE DATA PLATE W/PROPER HEAT STRIP INSTALLED AND FUSE UNIT ACCORDINGLY.3)PAINT EXPOSED PVC W/LATEX PAINT, NOT SPRAY ENAMEL.CORRECT AND RECALL FOR FINAL INSPECTION.