Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
8466 E PENA BLANCA DR
Apply Date:
01/22/2001
Applicant:
G T R HEATING AND AIR CONDITIONI
Description:
A/C&FURNACE:REPLACEMENT(APA)
Contractors:
  • G T R HEATING AND AIR CONDITIONI

Outstanding Activity Conditions

Permit Number - T01ME00051
Permit Status: Expired
Permit Description: A/C&FURNACE:REPLACEMENT(APA)
Total Outstanding Activity Conditions - 1
Date Name
01/22/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T01ME00051
Permite Description: A/C&FURNACE:REPLACEMENT(APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
01/31/2001 MECHANICAL - FINAL N/A Denied IVRS - Inspection 0999*
INSTALL TRAPS ON CONDENSATE DRAIN LINE.
SINGLE WALL VENT CONNECTOR MUST BE MIN 6" CLEARANCE FROM WALL. RECOMMEND USING DOUBLE WALL 90 DEGREE
LOW VOLTAGE WIRE TO CONDENSOR MUST BE PROTECTED FROM SUN DAMAGE
CORRECT AND RECALL FOR FINAL

Documents

File Name Document Type  
None DOCUMENTS VIEW