Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
2225 E SENECA ST
Address NEW:
2225 E SENECA ST
Apply Date:
11/06/2001
Applicant:
IRONWOOD ELECTRIC ''P''
Description:
UPGRADE:ELECTRIC 100MP TO 200 AMP (APA)
Contractors:
  • IRONWOOD ELECTRIC ''P''

Outstanding Activity Conditions

Permit Number - T01EL02694
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC 100MP TO 200 AMP (APA)
Total Outstanding Activity Conditions - 1
Date Name
11/06/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T01EL02694
Permite Description: UPGRADE:ELECTRIC 100MP TO 200 AMP (APA)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
11/13/2001 ELECTRIC - FINAL N/A Denied IVRS - Inspection 0245*NOTES 1.)INSTALL BOND BUSHINGS WHERE USING CONCENTRICS 250-94 NEC. 2.) USE INSULATING BUSHING ON FITTINGS WHERE WIRE SIZE IS #4 OR LARGER 300-4 NEC. 3.) EXPOSE GROUND RODS.