Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
2509 E HAMPTON ST
Apply Date:
09/25/2001
Applicant:
CHRIS MILLER
Description:
UPGRADE:ELECTRIC 120-200 AMP

Permit Reviews

Permit Number - T01EL02400
Permit Status: Final
Permit Description: UPGRADE:ELECTRIC 120-200 AMP
Start Date Submittal Complete Date Status  
09/25/2001 ELECTRICAL 09/25/2001 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T01EL02400
Permit Status: Final
Permit Description: UPGRADE:ELECTRIC 120-200 AMP
Total Outstanding Activity Conditions - 1
Date Name
09/25/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T01EL02400
Permit Description: UPGRADE:ELECTRIC 120-200 AMP
Total Completed Inspections - 3
Date Description Inspector Results Comments
10/22/2001 ELECTRIC - CABLE DROP JORTA Approved IVRS - Inspection 0999*1.) NEED TO ENTER TO VERIFY NEW WIRING A NOT 2.) NEED TO SEE NEW ROMEX TERMINATION 3.) LORD CONDUCTOR DANGEROUSLY CLOSE TO BUS BAR CANNOT PENETRATE THROUGH TOP & SEE LISTING 4.) 1 OPENING IN GROUND IN FRONT OF SERVICE IN VIOL. OF 110-26. 5.) EXPOSE 2ND ROD AND GAS BOND.
03/22/2002 PERMIT FINALED DSANTACR Approved
03/22/2002 ELECTRIC - SERVICE UPGRADE DSANTACR Approved IVRS - Inspection 0000*OK TO CLEAR INCREASE OK CABLE DROP OWNER REPLACED SERVICE PANEL SINCE LAST INSPECTION.

Documents

File Name Document Type  
None DOCUMENTS VIEW