SIGN:ELECTRIC:2434
Contractors:
  • ADDISIGNS

Outstanding Activity Conditions

Permit Number - T01EL01174
Permit Status: Closed
Permit Description: SIGN:ELECTRIC:2434
Total Outstanding Activity Conditions - 1
Date Name
05/10/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T01EL01174
Permite Description: SIGN:ELECTRIC:2434
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
06/19/2001 SIGN ELECTRIC N/A Denied IVRS - Inspection 0999*1)TRANSFORMER NOT DESIGNED FOR WET LOCATIONS.(MUST BE PUT IN WEATHER-PROOF BOX).2)SPLICES ON LOW-VOLTAGE SIDE OF TRANSFOMER NOT DONE TO BE WEATHER PROOF.