Permit: T01EL01125
Permit Details
Apply Date:
05/08/2001
Applicant:
SANTANA ANTHONY
Description:
ELECTRIC:RECONNECT
Outstanding Activity Conditions
Permit Number - T01EL01125
Permit Status: Expired
Permit Description: ELECTRIC:RECONNECT
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/08/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T01EL01125
Permite Description: ELECTRIC:RECONNECT
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/30/2001 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection 0210*1)THE ELECTRICAL WIRING IN THE GARAGE, STORAGE ROOM, AND LAUNDRY ROOM WILL HAVE TO BE CLEANED UP.BOXES MUST BE ATTACHED FIRMLY TO WALL OR CEILING, WIRING MUST BE PROPERTY TERMINATED AND CONNECTED TO BOX, AND ROMEX WIRE MUST BE PROPERLY SUPPORTED TO WOOD FRAMING.ELIMINATE UNNECCESSARY SLACK IN CABLES.2)THE CORD CONNECTION OF THE DISHWASHER SHOULD NOT BE SANDWICHED IN WALL AND CABINET.INSTALL A RECEPTACLE IN THE MACHINES CABINET SPACES.3)CHANGE BARE BULB FIXTURE IN MSTR. BED. CLOSET AND REPLACE WITH ONE THAT HAS GLASS COVERING OVER BULB.NO BARE BULBS IN CLOTHES CLOSETS.4)THE CLOSING OF THE CARPORT,THE STORAGE ROOM BEHIND THE LAUNDRY RM., AND THE REAR FAMILY ROOM AND PORCH APPEAR TO BE UNPERMITTED ADDITIONS.CAN YOU PROVIDE PROOF THESE WERE BUILT UNDER PERMIT? |