| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/12/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 07/07/2003 | COMPLETED |
| 10/08/2002 | RESUBMITTAL | 10/08/2002 | COMPLETED |
| 12/13/2001 | 3RD PARTY REVIEW-COMMERCIAL | 10/08/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM05964
Permit Status: C of o
Permit Description: NEW:APARTMENTS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/10/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM05964
Permit Description: NEW:APARTMENTS
Total Completed Inspections - 38
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2002 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | 1.) SOIL WATER TEST IS OK 2.) OK TO BACKFILL TRENCH 3.) NOTE: BLDG DRAIN IS STUBBED OUT @ TWO WAY C.O. ONLY. |
| 01/15/2003 | BUILDING PRE-SLAB | HLEYVA | Approved | IVRS - Inspection 0000* |
| 01/15/2003 | EXCAVATION/LAYOUT REBAR & ZON | HLEYVA | Approved | IVRS - Inspection 0000* |
| 01/16/2003 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection 0000*OK #4 TO REBAR. |
| 02/28/2003 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 03/11/2003 | EXT METAL CLIPS/EXT SHEATHING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 05/05/2003 | PLUMBING - YARD WTR LINE/TEST | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 05/05/2003 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 05/08/2003 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 05/15/2003 | PLUMBING - SEWER HCS CONNECT | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 05/21/2003 | STUCCO MESH | HLEYVA | Approved | IVRS - Inspection 0000* |
| 06/04/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000*/ 1) TWO OPTS |
| 06/06/2003 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 06/06/2003 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) BOXES AT KITCHEN CEILING MAY NEED EXTENDER RINGS PER 370.20 2) OK ROUGH ELECTRIC, OK TO COVER |
| 06/06/2003 | FRAMING | AQUIROZ | Approved | IVRS - Inspection 0000*/ 1) PENDING OTHER TRADE APPROVAL |
| 06/19/2003 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 08/14/2003 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000* SENT TO TEP 08/15AM |
| 11/04/2003 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 11/04/2003 | PLUMBING - TEMP POWER FOR TEST | JSTANLEY | Approved | IVRS - Inspection 0000$/ |
| 11/04/2003 | BUILDING - TEMP POWER FOR TEST | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 11/13/2003 | ELECTRIC - TEMP POWER FOR TEST | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) FINISH BREAKERS 2) CORRECTLY IDENTIFY UNGROUNDED CONDUCTORS 3) OK TEMP POWER FOR TEST |
| 04/14/2004 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 04/21/2004 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | |
| 04/26/2004 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection : The service is not per code.| 210* |
| 04/26/2004 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | |
| 04/26/2004 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | IVRS - Inspection : The service is not per code.| 210* |
| 05/06/2004 | FIRE - FINAL | LTHOMAS | Approved | |
| 05/06/2004 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 05/12/2004 | PLUMBING - ABOVE CEILING | JSTANLEY | Approved | |
| 05/12/2004 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection :*/ FINAL OK. |
| 12/03/2004 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 12/03/2004 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 12/03/2004 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 12/14/2004 | RIGHT OF WAY - FINAL | MOTERO | Approved | OK TO CLEAR |
| 12/29/2004 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :*/OK C/O |
| 01/03/2005 | BUILDING ABOVE CEILING | AQUIROZ | Approved | |
| 01/03/2005 | U VALUE FOR WINDOW | AQUIROZ | Approved | |
| 09/07/2006 | PERMIT FINALED | BGRANT | Approved |