Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address:
1125 E OHIO ST
Address NEW:
1125 E OHIO ST
Apply Date:
12/10/2001
Applicant:
3D ARCHITECTURAL DESIGNS
Description:
ADDITION:CARPORT
Architects:
  • 3D ARCHITECTURAL DESIGNS

Permit Reviews

Permit Number - T01CM05949
Permit Status: Expired
Permit Description: ADDITION:CARPORT
Start Date Submittal Complete Date Status  
06/21/2002 REVISION 06/21/2002 COMPLETED Review Details
12/10/2001 RESIDENTIAL BLDG/ZONING 04/16/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T01CM05949
Permit Status: Expired
Permit Description: ADDITION:CARPORT
Total Outstanding Activity Conditions - 1
Date Name
12/10/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T01CM05949
Permite Description: ADDITION:CARPORT
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
ROOF NAILING N/A Not Inspected
FRAMING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
ELECTRIC - INTERMEDIATE N/A Not Inspected
ELECTRIC - FINAL N/A Not Inspected
10/02/2003 BUILDING PRE-SLAB N/A Not ready for Inspection IVRS - Inspection 0000*/ 1) NO SLAB SHOWN ON PLAN (POST FOOTINGS ONLY READY-APPROVED, NO PRE-SLAB INSPECTION REQUIRED 2) PLANS CALL FOR 4" X 12" BEAMS 2 1/2" X 9" EXISTS) 3) WILL HAVE TO CHANGE OUT BEAMS TO WHAT PLACE CALLS FOR 4) NEED APPROVED PLOT PLAN T0 VERIFY SET BACK FROM FRONT PROPERTY LINE 5) MUST MAINTAIN MINIMUM 1/4" PER FOOT SLON ON ROOF 6) WHEN SETTING WOOD POSTS ON TO METAL ANCHORS USE A 1" METAL STAND OFF SPACER UNDER POST OR USE PRESSURE TREATED POSTS 7) WILL NEED APPROVED CONNECTIONS, BEAMS TO BEAMS AND BEAMS TO POSTS 8) IF YOU ARE GOING TO INSTALL SLAB, HAVE PLAN UPDATED 9) SET FORMS, BACKFILL, SCREED ETC.. THEN CALL FOR PRESLAB INSPECTION

Completed Inspections

Permit Status: Expired
Permit Number: T01CM05949
Permit Description: ADDITION:CARPORT
Total Completed Inspections - 1
Date Description Inspector Results Comments
10/08/2002 EXCAVATION/LAYOUT REBAR & ZON DBRITO Approved IVRS - Inspection 0000*