Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Address NEW:
1103 E KENTUCKY ST
Apply Date:
12/04/2001
Applicant:
JEFF'S DESIGN DRAFTING
Description:
REPAIR:FIRE DAMAGE

Outstanding Activity Conditions

Permit Number - T01CM05868
Permit Status: Expired
Permit Description: REPAIR:FIRE DAMAGE
Total Outstanding Activity Conditions - 1
Date Name
12/04/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T01CM05868
Permite Description: REPAIR:FIRE DAMAGE
Total Outstanding Inspections - 8
Last Inspection Date Description Inspector Results Comments
EXT METAL CLIPS/EXT SHEATHING N/A Not Inspected
ROOF NAILING N/A Not Inspected
FRAMING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
PLUMBING - INTERMEDIATE N/A Not Inspected
PLUMBING - FINAL N/A Not Inspected
05/02/2003 PLUMBING - GAS PRESS TEST FNL N/A Not ready for Inspection IVRS - Inspection 0000*
09/05/2003 ELECTRIC - FINAL N/A Denied IVRS - Inspection 0999*/1) SMOKE DETECTORS TO BE MIN. 36" AWAY FROM SUPPLY AIR GRILL. 2) DRYER AND RANGE TO BE 4 WIRE RECEPTACLES. 3) SUBMIT AS BUILTS FOR APPROVAL RE: UTILITY ROOM CHANGES. 4) COMPLETE ALL TRADES AND RECALL. 5) H20 HEATER (1) SUPPLY LINES TO BE CONNECTED. (2) INSTALL COMB/RELIEF VENTS. (3) INSTALL PTR TO EXTERIOR. (4) INSTALL FLUE PIPE THRU ROOF. 6) STOPPED INSPECTION.

Completed Inspections

Permit Status: Expired
Permit Number: T01CM05868
Permit Description: REPAIR:FIRE DAMAGE
Total Completed Inspections - 4
Date Description Inspector Results Comments
12/14/2001 ELECTRIC - TEMPORARY SERVICE HPEDROZA Approved IVRS - Inspection 0000*
05/02/2003 PLUMBING - GAS PRESSURE TEST ROHAVER Approved IVRS - Inspection 0000*
05/14/2003 ELECTRIC - INTERMEDIATE FGREER Approved IVRS - Inspection 0000*
08/06/2003 SHEET ROCK NAILING FGREER Approved IVRS - Inspection 0000*