Permit: T01CM05814
Permit Details
Apply Date:
11/29/2001
Applicant:
CANATSEY BUILDING AND DEVELOPMEN
Description:
SFR:TD #15-21-46
Contractors:
- CANATSEY BUILDING AND DEVELOPMEN
Permit Reviews
Permit Number - T01CM05814
Permit Status: Final
Permit Description: SFR:TD #15-21-46
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/29/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 11/30/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM05814
Permit Status: Final
Permit Description: SFR:TD #15-21-46
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/29/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T01CM05814
Permit Description: SFR:TD #15-21-46
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/07/2001 | ELECTRIC - UFER | ROHAVER | Approved | IVRS - Inspection 0000* |
| 12/07/2001 | EXCAVATION/LAYOUT REBAR & ZON | ROHAVER | Approved | IVRS - Inspection 0000*/ 1) PERIMETER FOOTING OK 2) IF EAST WALL FINISHED WALL SURFACE IS LESS THAN 3' TO P/L FIREROTING REQUIRED |
| 12/13/2001 | BUILDING PRE-SLAB | FGREER | Approved | IVRS - Inspection 0000* |
| 12/28/2001 | PLUMBING - SEWER HCS CONNECT | ROHAVER | Approved | IVRS - Inspection 0000* |
| 12/28/2001 | PLUMBING - YARD WTR LINE/TEST | ROHAVER | Approved | IVRS - Inspection 0000* |
| 12/28/2001 | PLUMBING - ROUGH, SOIL | ROHAVER | Approved | IVRS - Inspection 0000* |
| 01/30/2002 | ROOF NAILING | ROHAVER | Approved | IVRS - Inspection 0000* |
| 01/30/2002 | EXT METAL CLIPS/EXT SHEATHING | ROHAVER | Approved | IVRS - Inspection 0000* |
| 02/07/2002 | ELECTRIC - TEMPORARY SERVICE | HPEDROZA | Approved | IVRS - Inspection 0000* |
| 02/19/2002 | MECHANICAL - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection 0000* |
| 02/19/2002 | PLUMBING - GAS PRESSURE TEST | ROHAVER | Approved | IVRS - Inspection 0000* |
| 02/19/2002 | PLUMBING - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection 0000* |
| 02/19/2002 | ELECTRIC - INTERMEDIATE | ROHAVER | Approved | IVRS - Inspection 0000* |
| 02/19/2002 | U VALUE FOR WINDOW | ROHAVER | Approved | IVRS - Inspection 0000* |
| 02/19/2002 | FRAMING | ROHAVER | Approved | IVRS - Inspection 0000* |
| 02/27/2002 | STUCCO MESH | ROHAVER | Approved | IVRS - Inspection 0000* |
| 03/14/2002 | SHEET ROCK NAILING | ROHAVER | Approved | IVRS - Inspection 0000* |
| 05/06/2002 | PERMIT FINALED | ROHAVER | Approved | |
| 05/06/2002 | MECHANICAL - FINAL | ROHAVER | Approved | IVRS - Inspection 0000* |
| 05/06/2002 | PLUMBING - FINAL | ROHAVER | Approved | IVRS - Inspection 0000* |
| 05/06/2002 | ELECTRIC - FINAL | ROHAVER | Approved | IVRS - Inspection 0000* |
| 05/06/2002 | BUILDING - FINAL | ROHAVER | Approved | IVRS - Inspection 0000* |