Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Apply Date:
11/20/2001
Applicant:
GANSLINE, WILLIAM ROYAL
Description:
NEW:OFFICE
Architects:
  • GANSLINE, WILLIAM ROYAL
Contractors:
  • SUNRISE ASPHALT COMPANY ,

Permit Reviews

Permit Number - T01CM05689
Permit Status: C of o
Permit Description: NEW:OFFICE
Start Date Submittal Complete Date Status  
01/31/2002 SITE 02/20/2002 COMPLETED Review Details
01/31/2002 RESUBMITTAL 02/20/2002 COMPLETED Review Details
02/20/2002 RESUBMITTAL 02/25/2002 COMPLETED Review Details
02/20/2002 RESUBMITTAL 02/25/2002 COMPLETED Review Details
11/20/2001 COMMERCIAL NEW 01/14/2002 COMPLETED Review Details
11/20/2001 SITE 01/02/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T01CM05689
Permit Status: C of o
Permit Description: NEW:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
11/20/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T01CM05689
Permit Description: NEW:OFFICE
Total Completed Inspections - 34
Date Description Inspector Results Comments
03/01/2002 ELECTRIC - UFER RMAJUTA Approved IVRS - Inspection 0000*#4 COPPER TO REBAR & TAIL OUT FOR GAS PIPE BOND.
03/01/2002 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection 0000*
03/06/2002 STEM WALL/RETAINING WALL LHANLY Approved IVRS - Inspection 0000*
03/14/2002 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000* 1.) PRE-SLAB OK COPPER OK WRAP OK 2. OK FOR CONCRETE.
03/14/2002 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection 0000*
04/01/2002 ROOF NAILING LHANLY Approved IVRS - Inspection 0000*
04/08/2002 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection 0000*
04/08/2002 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection 0000*
04/08/2002 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000*
04/08/2002 FRAMING LHANLY Approved IVRS - Inspection 0000*
04/09/2002 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
04/11/2002 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved IVRS - Inspection 0000*BLDG. SEWER FROM HCS STUBB INTO P.L. TO TWO WAY C.O. IS OK 2.) NOTE CONTRACTOR SAID HE WILL REMOVE REVERSED TEST WYE AND SPLICE IN SOIL PIECE OF PIPE. 3.) OK TO BACKFILL TRENCH.
04/11/2002 ELECTRIC - INTERMEDIATE MCAPISTR Approved IVRS - Inspection 0000*
04/25/2002 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection 0000*
05/09/2002 ELECTRIC - TEMP POWER FOR TEST JORTA Approved IVRS - Inspection 0000*ADD TEMP POWER TO JOB CARD PER STEVE.
05/09/2002 ELECTRIC - CABLE DROP JORTA Approved IVRS - Inspection 0000* SIGN OFF SHEET LEFT AT PREMISER FOR THE TEMP F & T.
05/10/2002 MECHANICAL - TEMP PWR FOR TEST JMILITEL Approved IVRS - Inspection 0000*
05/10/2002 PLUMBING - TEMP POWER FOR TEST TRINIVJR Approved IVRS - Inspection 0000* 1.) GAS & WATER LINES HAVE BEEN BONDED 2.) OK FOR TEMP POWER.
05/10/2002 BUILDING - TEMP POWER FOR TEST LHANLY Approved IVRS - Inspection 0000*
05/29/2002 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0000*OK FOR C OF O.
05/29/2002 ENGINEERING - FINAL DROBERTS Approved
05/29/2002 FIRE - FINAL WCUMMING Approved
05/29/2002 PLUMBING - FINAL FMCCLURE Approved IVRS - Inspection 0000*
05/29/2002 OUTDOOR LIGHTING FINAL MCAPISTR Approved IVRS - Inspection 0000*
05/29/2002 ELECTRIC - FINAL MCAPISTR Approved IVRS - Inspection 0000*
05/29/2002 ELECTRIC - ABOVE CEILING MCAPISTR Approved IVRS - Inspection 0000*
05/30/2002 RIGHT OF WAY - FINAL PWHIDDON Approved
05/31/2002 PLUMBING - PROGRESS FMCCLURE Approved
05/31/2002 PLUMBING - ABOVE CEILING FMCCLURE Approved
05/31/2002 ELECTRIC - CONSTRUCTION POWER MCAPISTR Approved
05/31/2002 ELECTRIC - UNDERGROUND MCAPISTR Approved
05/31/2002 BUILDING - FINAL LHANLY Approved IVRS - Inspection 0000*
06/03/2002 PERMIT FINALED PWHIDDON Approved
06/03/2002 SIGN - FINAL DJOHNSTO Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
None DOCUMENTS VIEW