Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T01CM05489
Permit Details
Apply Date:
11/06/2001
Applicant:
FIRST WORTHINGTON
Description:
NEW:APARTMENT BUILDING A
Contractors:
- T A-WALLICK LLC
Permit Reviews
Permit Number - T01CM05489
Permit Status: C of o
Permit Description: NEW:APARTMENT BUILDING A
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/06/2001 | OTHER | 11/07/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM05489
Permit Description: NEW:APARTMENT BUILDING A
Total Completed Inspections - 36
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2001 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection 0000*PRE SLAB OK TEST ON 2' COPPER SERVICE OK. |
| 11/20/2001 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection 0000*OK 2 - 4 UFERS OK 1" PVC UNDER SLAB. |
| 11/20/2001 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 11/21/2001 | BUILDING PRE-SLAB | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 11/21/2001 | EXCAVATION/LAYOUT REBAR & ZON | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 12/19/2001 | ROOF NAILING | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 12/21/2001 | STUCCO MESH | EMONAHAN | Approved | IVRS - Inspection 0000$PA @ PANEL BOXES. |
| 12/28/2001 | EXT METAL CLIPS/EXT SHEATHING | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 01/06/2002 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000*1.) APPROVED 01/04/2002 BY R MYERS. |
| 01/15/2002 | PLUMBING - ABOVE CEILING | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 01/15/2002 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000*WASTE & OVERFLOW OK. |
| 01/17/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 01/22/2002 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 01/22/2002 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 01/23/2002 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection 0000* |
| 01/25/2002 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 01/25/2002 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000*OK ROUGH ELECT. |
| 02/08/2002 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 03/25/2002 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 04/02/2002 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 04/02/2002 | PLUMBING - YARD WTR LINE/TEST | JSTANLEY | Approved | IVRS - Inspection 0000*PROVIDE TESTING INFO |
| 04/15/2002 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | IVRS - Inspection 0000*OK CABLE DROP ONLY. |
| 04/17/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000*BLDG #3 |
| 04/26/2002 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection 0000*OK FINAL SUBJECT TO OTHER INSPECTION. |
| 04/30/2002 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 04/30/2002 | PLUMBING - TEMP POWER FOR TEST | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 04/30/2002 | ELECTRIC - TEMP POWER FOR TEST | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 04/30/2002 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 04/30/2002 | BUILDING - TEMP POWER FOR TEST | AMATHIES | Approved | IVRS - Inspection 0000* |
| 05/09/2002 | SIGN - FINAL | JYBARRA | Approved | |
| 05/17/2002 | FIRE - FINAL | LTHOMAS | Approved | |
| 05/30/2002 | RIGHT OF WAY - FINAL | SLONG | Approved | OK PER STEVE LONG |
| 08/07/2002 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 12/17/2002 | NPPO - FINAL | PGILBERT | Approved | |
| 12/17/2002 | LANDSCAPE - FINAL | PGILBERT | Approved | |
| 01/16/2003 | PERMIT FINALED | SLONG | Approved |