Permit: T01CM05376
Permit Details
Apply Date:
10/29/2001
Applicant:
K B HOME OF TUCSON ****''T''
Description:
SFR:TD#15-22-46
Contractors:
- K B HOME OF TUCSON ****''T''
Permit Reviews
Permit Number - T01CM05376
Permit Status: Final
Permit Description: SFR:TD#15-22-46
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/29/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 10/31/2001 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T01CM05376
Permit Description: SFR:TD#15-22-46
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/29/2001 | PLUMBING - YARD WTR LINE/TEST | DQUINN | Approved | IVRS - Inspection 0000* |
11/29/2001 | PLUMBING - ROUGH, SOIL | DQUINN | Approved | IVRS - Inspection 0000* |
12/07/2001 | ELECTRIC - UFER | HPEDROZA | Approved | IVRS - Inspection 0000* |
12/07/2001 | BUILDING PRE-SLAB | HPEDROZA | Approved | IVRS - Inspection 0000* |
12/07/2001 | EXCAVATION/LAYOUT REBAR & ZON | HPEDROZA | Approved | IVRS - Inspection 0000* |
12/27/2001 | PLUMBING - SEWER HCS CONNECT | RFREIDIN | Approved | IVRS - Inspection 0000* |
12/27/2001 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection 0000* |
12/27/2001 | EXT METAL CLIPS/EXT SHEATHING | RFREIDIN | Approved | IVRS - Inspection 0000*/ 1) NO WATER TEST ON SEWER LINE 2) WRONG SIZE NAILS USED IN ALL LOAD BEARING HANGERS 3) MISSING LATERAL BRACING ON MANY TRUSSES 4) MISSING HD'S 5) NEED DETAIL FOR TRUSS TO GIRDER HANGER TYPES AND SIZES 6) NEED SHEAR TRANSFER DETAIL FOR GARAGE WALL |
01/04/2002 | ELECTRIC - TEMPORARY SERVICE | DQUINN | Approved | IVRS - Inspection 0000* |
01/04/2002 | ELECTRIC - CABLE DROP | DQUINN | Approved | IVRS - Inspection 0000* |
01/10/2002 | PLUMBING - GAS PRESSURE TEST | DQUINN | Approved | IVRS - Inspection 0000* |
01/11/2002 | MECHANICAL - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection 0000* |
01/11/2002 | PLUMBING - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection 0000* |
01/11/2002 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection 0000* |
01/11/2002 | FRAMING | DQUINN | Approved | IVRS - Inspection 0000* |
01/16/2002 | STUCCO MESH | DQUINN | Approved | IVRS - Inspection 0000* |
01/23/2002 | SHEET ROCK NAILING | DQUINN | Approved | IVRS - Inspection 0000* |
02/27/2002 | MECHANICAL - FINAL | DQUINN | Approved | IVRS - Inspection 0999* |
02/27/2002 | PLUMBING - FINAL | DQUINN | Approved | IVRS - Inspection 0999* |
02/27/2002 | ELECTRIC - FINAL | DQUINN | Approved | IVRS - Inspection 0999* |
02/27/2002 | BUILDING - FINAL | DQUINN | Approved | IVRS - Inspection 0999*/ 1) MISSING FLUE CAPS 2) PAINT CONDENSATE DRAIN AT EXTERIOR 3) CLAMP A/C WIRE TO HOUSE 4) NEED 8' LADDER FOR ATTIC ACCESS 5) DISHWASHER DRAIN NOT INSTALLED YET |
03/01/2002 | PERMIT FINALED | RFREIDIN | Approved |