Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T01CM05155
Permit Details
Apply Date:
10/15/2001
Applicant:
METRO PERMIT EXPRESS, INC
Description:
RECREATION BUILDING
Architects:
- EGLIN, EVAN SAR
Contractors:
- R A S BUILDERS
Permit Reviews
Permit Number - T01CM05155
Permit Status: Final
Permit Description: RECREATION BUILDING
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/15/2001 | COMMERCIAL NEW | 01/30/2002 | COMPLETED |
10/15/2001 | SITE | 01/30/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM05155
Permit Status: Final
Permit Description: RECREATION BUILDING
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/15/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T01CM05155
Permit Description: RECREATION BUILDING
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/20/2002 | PLUMBING - ROUGH, SOIL | FMCCLURE | Approved | IVRS - Inspection 0000* |
03/21/2002 | PLUMBING - INTERMEDIATE | FMCCLURE | Approved | IVRS - Inspection 0000* |
03/29/2002 | PLUMBING - SEWER HCS CONNECT | SLONG | Approved | |
03/29/2002 | PLUMBING - GAS PRESSURE TEST | SLONG | Approved | |
03/29/2002 | PLUMBING - YARD WTR LINE/TEST | SLONG | Approved | GAS @ 20PSI LISTED TRANSITION FITTING TAPE TRACER WIRE TO GAS PIPE. |
04/03/2002 | FRAMING | RSUBA | Approved | IVRS - Inspection 0000* |
04/03/2002 | ROOF NAILING | RSUBA | Approved | IVRS - Inspection 0000* |
04/09/2002 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
04/30/2002 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
04/30/2002 | FIRE - FINAL | KFOSTER | Approved | |
04/30/2002 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*1.) PLUMBING FINAL OK 2.) OK FOR C OF O PENDING ANY OTHER INSPECTION. |
04/30/2002 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000* |
04/30/2002 | ELECTRIC - UFER | MCAPISTR | Approved | |
04/30/2002 | BUILDING - FINAL | RSUBA | Approved | IVRS - Inspection 0000* |
04/30/2002 | REINFORCED MASONRY PRE-GROUT | RSUBA | Approved | |
04/30/2002 | BUILDING PRE-SLAB | RSUBA | Approved | |
04/30/2002 | EXCAVATION/LAYOUT REBAR & ZON | RSUBA | Approved | |
04/30/2002 | EXCAVATION/LAYOUT REBAR & ZON | RSUBA | Approved | |
11/19/2008 | ENGINEERING - FINAL | JFEMLING | Approved | All items on grading permit complete. |
12/03/2010 | RIGHT OF WAY - FINAL | LHANLY | Approved | |
12/03/2010 | LANDSCAPE - FINAL | LHANLY | Approved |