Permit: T01CM04794
Permit Details
Status:
Closed
Type:
SINGLE FAMILY OTHER
Address:
4648 E FAIRMOUNT ST #02
Address NEW:
4648 E FAIRMOUNT ST #02
Apply Date:
09/25/2001
Applicant:
N/A
Description:
GAS/AC
Contractors:
- DEWOODY'S HEATING AND AIR CONDIT
Permit Reviews
Permit Number - T01CM04794
Permit Status: Closed
Permit Description: GAS/AC
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/25/2001 | RESIDENTIAL BLDG/ZONING | 09/25/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM04794
Permit Status: Closed
Permit Description: GAS/AC
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/25/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T01CM04794
Permite Description: GAS/AC
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/22/2002 | ELECTRIC - INTERMEDIATE | N/A | Denied | IVRS - Inspection 0245*NOTES 1.) SCH 40PVC NOT APPROVED PER ART 347-3 NEC SEE PREVIOUS WRITE UP. ALSO CITY OF TUCSON ORDINANCE #9287. |
| 11/20/2001 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection 0999*1.) LIQUIDTIGH FLEX NON METCALLIC NOT TO BE INSTALLED WHERE SUBJECT TO PHYSICAL DAMAGE (CAN BE WALKED ON) 2.) FUSING CALLS FOR 25A MAX NOT 30A 3.) DISCONNECT HAS NO BUSHING OR CONNECTOR BETWEEN IT AND UNIT. |
Completed Inspections
Permit Status: Closed
Permit Number: T01CM04794
Permit Description: GAS/AC
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2001 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0999*PROVIDE A CONDENSATE DRAIN LINE ON AC UNIT ELECTRICAL WIRING TO DISCONNECT MUST BE IN CONDUIT. PROVIDE A ROOF JACK AT ROOF PENETRATION. UNIT NOT FUSED CORRECTLY. BLOCK & CLAMP GAS PIPE ON ROOF. RECALL FOR FINAL INSPECTION |
| 01/22/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000* |