Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T01CM04635
Permit Details
Apply Date:
09/14/2001
Applicant:
HUNTER AND ASSOCIATES ,
Description:
SFR:NEW
Contractors:
- HUNTER AND ASSOCIATES ,
Permit Reviews
Permit Number - T01CM04635
Permit Status: C of o
Permit Description: SFR:NEW
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/04/2002 | REVISION | 01/04/2002 | COMPLETED |
09/14/2001 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 10/24/2001 | COMPLETED |
10/22/2001 | RESUBMITTAL | 10/25/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM04635
Permit Status: C of o
Permit Description: SFR:NEW
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/14/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM04635
Permit Description: SFR:NEW
Total Completed Inspections - 25
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/08/2001 | EXCAVATION/LAYOUT REBAR & ZON | DBRITO | Approved | IVRS - Inspection 0000* |
11/18/2001 | STEM WALL/RETAINING WALL | DBRITO | Approved | IVRS - Inspection 0000*/ 1) OK TO GROUT |
11/30/2001 | PLUMBING - SEWER HCS CONNECT | DBRITO | Approved | IVRS - Inspection 0000* |
11/30/2001 | PLUMBING - YARD WTR LINE/TEST | DBRITO | Approved | IVRS - Inspection 0000* |
11/30/2001 | PLUMBING - ROUGH, SOIL | DBRITO | Approved | IVRS - Inspection 0000* |
11/30/2001 | ELECTRIC - UFER | DBRITO | Approved | IVRS - Inspection 0000* |
12/06/2001 | BUILDING PRE-SLAB | DBRITO | Approved | IVRS - Inspection 0000*/ 1) ALL OK EXCEPT PORCH FOOTINGS |
12/06/2001 | BUILDING PRE-SLAB | DBRITO | Approved | IVRS - Inspection 0000* |
12/20/2001 | REINFORCED MASONRY PRE-GROUT | DBRITO | Approved | 1) 1ST LIFT OK, CALL BACK AT 10' |
01/10/2002 | ELECTRIC - CABLE DROP | DBRITO | Approved | IVRS - Inspection 0000* |
01/15/2002 | ELECTRIC - CONSTRUCTION POWER | DBRITO | Approved | IVRS - Inspection 0999*/ 1) PROVIDE GFCI OUTLET FOR POWER (20 AMP) |
03/14/2002 | ROOF NAILING | HPEDROZA | Approved | IVRS - Inspection 0000* |
05/01/2002 | MECHANICAL - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0000* |
05/01/2002 | PLUMBING - GAS PRESSURE TEST | DBRITO | Approved | IVRS - Inspection 0000* |
05/01/2002 | PLUMBING - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0000* |
05/16/2002 | ELECTRIC - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0000* |
05/16/2002 | SHEET ROCK NAILING | DBRITO | Approved | IVRS - Inspection 0000* |
05/16/2002 | FRAMING | DBRITO | Approved | IVRS - Inspection 0000* |
07/22/2002 | PERMIT FINALED | DBRITO | Approved | |
07/22/2002 | MECHANICAL - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
07/22/2002 | PLUMBING - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
07/22/2002 | PLUMBING - GAS PRESS TEST FNL | DBRITO | Approved | IVRS - Inspection 0000* |
07/22/2002 | ELECTRIC - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
07/22/2002 | BUILDING - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
07/22/2002 | U VALUE FOR WINDOW | DBRITO | Approved | IVRS - Inspection 0000* |