Permit: T01CM04573
Permit Details
Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
1922 S SANTA RITA AV
Address NEW:
1922 S SANTA RITA AV
Apply Date:
09/13/2001
Applicant:
HABITAT FOR HUMANITY
Description:
SFR:TD#12-18-99
Contractors:
- T J BEDNAR & COMPANY
Permit Reviews
Permit Number - T01CM04573
Permit Status: C of o
Permit Description: SFR:TD#12-18-99
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/04/2002 | REVISION | 04/08/2002 | COMPLETED |
| 09/13/2001 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 09/13/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM04573
Permit Description: SFR:TD#12-18-99
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2001 | ROOF NAILING | HPEDROZA | Approved | IVRS - Inspection 0000* |
| 10/24/2001 | EXT METAL CLIPS/EXT SHEATHING | HPEDROZA | Approved | IVRS - Inspection 0000* |
| 02/08/2002 | MECHANICAL - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection 0999* |
| 02/08/2002 | PLUMBING - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection 0999* |
| 02/08/2002 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection 0999*/ 1) GAS PIPING NOT RUN TO HW HEATER AND FURNACE PER PLAN 2) DISTRIBUTION DUCTING NOT PER PLAN IN SOUTH EAST AND SOUTHWEST BEDROOMS 3) WIRING, WHERE GAUGE SIZE PERMITS, SHOULD BE ROLLED AND INSIDE BOXES 4) SMOKIES SHOULD BE LOWERED IN THE SOUTHEAST BEDROOM AND HALL WAY 5) ALTHOUGH THE FRAME INSPECTION WAS NOT CALLED, THERE ARE A FEW THINGS TO SUGGEST: ALL BEARING WALL HEADERS AND CRIPPLES SHOULD BE SHIMMED TIGHT, THE INTERIOR KITCHEN WALL NEEDS STIFFENING 3) THE EXTERIOR BEARING WALL STUD, BEHIND THE SHOWER STALL, HAS BEEN OVER BORED, WITH NO EXTERIOR SIDE PROTECTION FROM FASTENERS |
| 02/08/2002 | FRAMING | DQUINN | Approved | IVRS - Inspection 0999* |
| 04/16/2002 | ELECTRIC - UFER | FGREER | Approved | IVRS - Inspection 0000* |
| 04/16/2002 | EXCAVATION/LAYOUT REBAR & ZON | FGREER | Approved | IVRS - Inspection 0000* |
| 04/22/2002 | STEM WALL/RETAINING WALL | MTESTER | Approved | IVRS - Inspection 0000* |
| 06/12/2002 | PLUMBING - SEWER HCS CONNECT | MTESTER | Approved | IVRS - Inspection 0000* |
| 06/12/2002 | PLUMBING - YARD WTR LINE/TEST | MTESTER | Approved | IVRS - Inspection 0000* |
| 06/12/2002 | PLUMBING - ROUGH, SOIL | MTESTER | Approved | IVRS - Inspection 0000* |
| 06/12/2002 | ELECTRIC - TEMPORARY SERVICE | MTESTER | Approved | IVRS - Inspection 0000* |
| 06/12/2002 | ELECTRIC - CABLE DROP | MTESTER | Approved | IVRS - Inspection 0000* |
| 06/25/2002 | BUILDING PRE-SLAB | MTESTER | Approved | IVRS - Inspection 0000* |
| 10/17/2002 | PLUMBING - GAS PRESSURE TEST | EDURAZO | Approved | IVRS - Inspection 0000* |
| 10/17/2002 | STUCCO MESH | EDURAZO | Approved | IVRS - Inspection 0000* |
| 11/19/2002 | PERMIT FINALED | MTESTER | Approved | |
| 11/19/2002 | MECHANICAL - FINAL | MTESTER | Approved | IVRS - Inspection 0000* |
| 11/19/2002 | PLUMBING - FINAL | MTESTER | Approved | IVRS - Inspection 0000* |
| 11/19/2002 | ELECTRIC - FINAL | MTESTER | Approved | IVRS - Inspection 0000* |
| 11/19/2002 | BUILDING - FINAL | MTESTER | Approved | IVRS - Inspection 0000* |
| 11/19/2002 | SHEET ROCK NAILING | MTESTER | Approved | |
| 11/19/2002 | U VALUE FOR WINDOW | MTESTER | Approved |