Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address NEW:
1922 S SANTA RITA AV
Apply Date:
09/13/2001
Applicant:
HABITAT FOR HUMANITY
Description:
SFR:TD#12-18-99
Contractors:
  • T J BEDNAR & COMPANY

Permit Reviews

Permit Number - T01CM04573
Permit Status: C of o
Permit Description: SFR:TD#12-18-99
Start Date Submittal Complete Date Status  
04/04/2002 REVISION 04/08/2002 COMPLETED Review Details
09/13/2001 RESIDENTIAL BLDG/ZONING/FLOOD/WWM 09/13/2001 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T01CM04573
Permit Description: SFR:TD#12-18-99
Total Completed Inspections - 24
Date Description Inspector Results Comments
10/24/2001 ROOF NAILING HPEDROZA Approved IVRS - Inspection 0000*
10/24/2001 EXT METAL CLIPS/EXT SHEATHING HPEDROZA Approved IVRS - Inspection 0000*
02/08/2002 MECHANICAL - INTERMEDIATE DQUINN Approved IVRS - Inspection 0999*
02/08/2002 PLUMBING - INTERMEDIATE DQUINN Approved IVRS - Inspection 0999*
02/08/2002 ELECTRIC - INTERMEDIATE DQUINN Approved IVRS - Inspection 0999*/ 1) GAS PIPING NOT RUN TO HW HEATER AND FURNACE PER PLAN 2) DISTRIBUTION DUCTING NOT PER PLAN IN SOUTH EAST AND SOUTHWEST BEDROOMS 3) WIRING, WHERE GAUGE SIZE PERMITS, SHOULD BE ROLLED AND INSIDE BOXES 4) SMOKIES SHOULD BE LOWERED IN THE SOUTHEAST BEDROOM AND HALL WAY 5) ALTHOUGH THE FRAME INSPECTION WAS NOT CALLED, THERE ARE A FEW THINGS TO SUGGEST: ALL BEARING WALL HEADERS AND CRIPPLES SHOULD BE SHIMMED TIGHT, THE INTERIOR KITCHEN WALL NEEDS STIFFENING 3) THE EXTERIOR BEARING WALL STUD, BEHIND THE SHOWER STALL, HAS BEEN OVER BORED, WITH NO EXTERIOR SIDE PROTECTION FROM FASTENERS
02/08/2002 FRAMING DQUINN Approved IVRS - Inspection 0999*
04/16/2002 ELECTRIC - UFER FGREER Approved IVRS - Inspection 0000*
04/16/2002 EXCAVATION/LAYOUT REBAR & ZON FGREER Approved IVRS - Inspection 0000*
04/22/2002 STEM WALL/RETAINING WALL MTESTER Approved IVRS - Inspection 0000*
06/12/2002 PLUMBING - SEWER HCS CONNECT MTESTER Approved IVRS - Inspection 0000*
06/12/2002 PLUMBING - YARD WTR LINE/TEST MTESTER Approved IVRS - Inspection 0000*
06/12/2002 PLUMBING - ROUGH, SOIL MTESTER Approved IVRS - Inspection 0000*
06/12/2002 ELECTRIC - TEMPORARY SERVICE MTESTER Approved IVRS - Inspection 0000*
06/12/2002 ELECTRIC - CABLE DROP MTESTER Approved IVRS - Inspection 0000*
06/25/2002 BUILDING PRE-SLAB MTESTER Approved IVRS - Inspection 0000*
10/17/2002 PLUMBING - GAS PRESSURE TEST EDURAZO Approved IVRS - Inspection 0000*
10/17/2002 STUCCO MESH EDURAZO Approved IVRS - Inspection 0000*
11/19/2002 PERMIT FINALED MTESTER Approved
11/19/2002 MECHANICAL - FINAL MTESTER Approved IVRS - Inspection 0000*
11/19/2002 PLUMBING - FINAL MTESTER Approved IVRS - Inspection 0000*
11/19/2002 ELECTRIC - FINAL MTESTER Approved IVRS - Inspection 0000*
11/19/2002 BUILDING - FINAL MTESTER Approved IVRS - Inspection 0000*
11/19/2002 SHEET ROCK NAILING MTESTER Approved
11/19/2002 U VALUE FOR WINDOW MTESTER Approved

Documents

File Name Document Type  
T01CM04573-1 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW
T01CM04573 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW
T01CM04573 DOCS 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW