Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address:
124 W 18TH ST 12
Apply Date:
09/11/2001
Applicant:
METRO EXPRESS PERMIT
Description:
BARRIO VIEJO ELDERLY HOUSING / BUILDING #12
Contractors:
  • T A-WALLICK LLC

Permit Reviews

Permit Number - T01CM04489
Permit Status: C of o
Permit Description: BARRIO VIEJO ELDERLY HOUSING / BUILDING #12
Start Date Submittal Complete Date Status  
09/11/2001 COMMERCIAL NEW 08/15/2002 COMPLETED Review Details
12/05/2002 REVISION 01/03/2003 STOPPED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T01CM04489
Permit Description: BARRIO VIEJO ELDERLY HOUSING / BUILDING #12
Total Completed Inspections - 36
Date Description Inspector Results Comments
11/20/2002 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection 0000*
11/20/2002 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*
1.) ABS DWV UNDERGROUND OK
WATER TEST ON TEN FOOT RISER OK
TIE-IN TO HCS OK TRANSITION FITTING OK
2.) OK TO BACKFILL.
12/16/2002 ELECTRIC - UFER DSANTACR Approved IVRS - Inspection 0000*
12/18/2002 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection 0000*1.) TYPE "L" UNDERSLAB W/SIL-FOS'D JOINT OK. PRESSURE TEST 60# OK.
2.) OK FOR CONCRETE.
12/18/2002 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection 0000*
12/18/2002 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection 0000*
03/04/2003 ROOF NAILING AMATHIES Approved IVRS - Inspection 0000*
03/04/2003 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved IVRS - Inspection 0000*
03/10/2003 U VALUE FOR WINDOW AMATHIES Approved IVRS - Inspection 0000*
03/20/2003 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000*
1.) ABS DWV THRU ROOF OK WATER TEST OK
2.) CPVC WATER PIPING OK
PRESSURE TEST OK
3.) CLOSET FLANGES OK
4.) OK TO COVER ALL AREAS.
03/20/2003 STUCCO MESH AMATHIES Approved IVRS - Inspection 0000*
03/25/2003 FRAMING AMATHIES Approved IVRS - Inspection 0000*
03/28/2003 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
03/28/2003 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection 0000*OK WALLS CEILINGS.
04/01/2003 ELECTRIC - CABLE DROP DSANTACR Approved IVRS - Inspection 0000*SENT TO TEP ON 4/2/03 AT 9:15AM
04/03/2003 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection 0000*
04/10/2003 MECHANICAL - TEMP PWR FOR TEST CWILLIAM Approved #12
04/10/2003 PLUMBING - TEMP POWER FOR TEST JSTANLEY Approved IVRS - Inspection 0000*
04/10/2003 ELECTRIC - TEMP POWER FOR TEST DSANTACR Approved IVRS - Inspection 0000*SENT TO TEP ON 4/11/03 AT 9:15AM SEE NOTE FOR BLD #1 T01CM04466.
OK TO CLEAR TEMP POWER FOR TEST BLD #12. UNITS #12101,12102,12103,12104,12105,12106. SUBJECT TO BOND POSTING OTHER APPROVALS.
04/10/2003 BUILDING - TEMP POWER FOR TEST AMATHIES Approved IVRS - Inspection 0000*
05/02/2003 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*6 apts.
05/09/2003 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection 0000*
06/08/2003 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection 0000*/ 1) PLBG FINAL IS OK 2) OK FOR C OF O
06/11/2003 FIRE - FINAL JEGAN Approved IVRS - Inspection 0000*
06/11/2003 FIRE SPKLR - FINAL JEGAN Approved IVRS - Inspection 0000*
06/11/2003 FIRE SPKLR - OH PIPING & HYDRO JEGAN Approved IVRS - Inspection 0000*
06/11/2003 FIRE SPKLR - UG PIPING FLUSH JEGAN Approved IVRS - Inspection 0000*
06/11/2003 FIRE SPKLR - UG, PIPING, HYDRO JEGAN Approved IVRS - Inspection 0000*
07/03/2003 SIGN - FINAL JYBARRA Approved IVRS - Inspection 0000*
07/07/2003 LANDSCAPE - FINAL PGILBERT Approved ROSES PLANT. REPLACE DYING PLANTS. REMOVE PG FROM SIDEWALK.
07/09/2003 RIGHT OF WAY - FINAL LLOPEZ Approved
07/17/2003 BUILDING - FINAL AMATHIES Approved IVRS - Inspection 0000*
07/17/2003 REINFORCED MASONRY PRE-GROUT AMATHIES Approved
07/18/2003 PERMIT FINALED PGILBERT Approved
07/18/2003 NPPO - FINAL PGILBERT Approved
07/18/2003 ENGINEERING - FINAL DROBERTS Approved