Permit: T01CM04477
Permit Details
Apply Date:
09/11/2001
Applicant:
CONTRAVEST PROPERTIES
Description:
SFR:TD#15-21-40
Contractors:
- CONTRAVEST PROPERTIES
Permit Reviews
Permit Number - T01CM04477
Permit Status: C of o
Permit Description: SFR:TD#15-21-40
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/11/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 09/17/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM04477
Permit Status: C of o
Permit Description: SFR:TD#15-21-40
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/11/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM04477
Permit Description: SFR:TD#15-21-40
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/17/2001 | PLUMBING - SEWER HCS CONNECT | BSTEVENS | Approved | IVRS - Inspection 0000* |
10/17/2001 | PLUMBING - YARD WTR LINE/TEST | BSTEVENS | Approved | IVRS - Inspection 0000* |
10/17/2001 | PLUMBING - ROUGH, SOIL | BSTEVENS | Approved | IVRS - Inspection 0000* |
10/24/2001 | ELECTRIC - UFER | BSTEVENS | Approved | IVRS - Inspection 0000* |
10/24/2001 | BUILDING PRE-SLAB | BSTEVENS | Approved | IVRS - Inspection 0000* |
10/24/2001 | EXCAVATION/LAYOUT REBAR & ZON | BSTEVENS | Approved | IVRS - Inspection 0000* |
11/07/2001 | ELECTRIC - TEMPORARY SERVICE | BSTEVENS | Approved | IVRS - Inspection 0000* |
11/07/2001 | ELECTRIC - CABLE DROP | BSTEVENS | Approved | IVRS - Inspection 0000* |
12/06/2001 | ROOF NAILING | BSTEVENS | Approved | IVRS - Inspection 0000* |
12/06/2001 | EXT METAL CLIPS/EXT SHEATHING | BSTEVENS | Approved | IVRS - Inspection 0000* |
12/28/2001 | MECHANICAL - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0000* |
12/28/2001 | PLUMBING - GAS PRESSURE TEST | BSTEVENS | Approved | IVRS - Inspection 0000* |
12/28/2001 | PLUMBING - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0999* |
12/28/2001 | ELECTRIC - INTERMEDIATE | BSTEVENS | Approved | IVRS - Inspection 0999* |
12/28/2001 | FRAMING | BSTEVENS | Approved | IVRS - Inspection 0999*/ 1) SECRUE ELECTRIC HOMERUNS IN WALL CAVITY 2) SUPPORT VENT ABOVE EAST BATH 3) STUB OUT DRAIN AT EAST BATH LAV. 4) A WATER TEST IS REQUIRED ON THE ENTIRE DWV SYSTEM 5) ELECTRIC TO ROOF MOUNTED A/C MUST BE STUFFED THROUGH ROOF WITH WEATHER TIGHT SEAL |
04/11/2002 | SHEET ROCK NAILING | BSTEVENS | Approved | IVRS - Inspection 0000* |
04/23/2002 | STUCCO MESH | BSTEVENS | Approved | IVRS - Inspection 0000* |
08/30/2002 | PERMIT FINALED | BSTEVENS | Approved | |
08/30/2002 | MECHANICAL - FINAL | BSTEVENS | Approved | IVRS - Inspection 0000* |
08/30/2002 | PLUMBING - FINAL | BSTEVENS | Approved | IVRS - Inspection 0000* |
08/30/2002 | ELECTRIC - FINAL | BSTEVENS | Approved | IVRS - Inspection 0000* |
08/30/2002 | ELECTRIC - UNDERGROUND | BSTEVENS | Approved | |
08/30/2002 | BUILDING - FINAL | BSTEVENS | Approved | IVRS - Inspection 0000* |
09/03/2002 | U VALUE FOR WINDOW | BSTEVENS | Approved |