Permit: T01CM04421
Permit Details
Status:
Withdrwn
Type:
INDUSTRIAL ADDITION
Address:
6620 S MEMORIAL PL #100
Address NEW:
6620 S MEMORIAL PL #100
Apply Date:
09/07/2001
Applicant:
N/A
Description:
ADDITION:INSTALLATION OF 17 INFRARED HEATING UNITS TO WAREHOUSE SUSPENDED FROM ROOF STRUCTURE
Contractors:
- CHESTNUT CONSTRUCTION CORPORATIO
Permit Reviews
Permit Number - T01CM04421
Permit Status: Withdrwn
Permit Description: ADDITION:INSTALLATION OF 17 INFRARED HEATING UNITS TO WAREHOUSE SUSPENDED FROM ROOF STRUCTURE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/07/2001 | COMMERCIAL TI | 09/11/2001 | COMPLETED |
| 10/26/2001 | REVISION | 10/26/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM04421
Permit Status: Withdrwn
Permit Description: ADDITION:INSTALLATION OF 17 INFRARED HEATING UNITS TO WAREHOUSE SUSPENDED FROM ROOF STRUCTURE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/07/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Withdrwn
Permit Number: T01CM04421
Permite Description: ADDITION:INSTALLATION OF 17 INFRARED HEATING UNITS TO WAREHOUSE SUSPENDED FROM ROOF STRUCTURE
Total Outstanding Inspections - 11
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EXCAVATION/LAYOUT REBAR & ZON | N/A | Not Inspected | ||
| FRAMING | N/A | Not Inspected | ||
| BUILDING - FINAL | N/A | Not Inspected | ||
| FIRE - FINAL | N/A | Not Inspected | ||
| ENGINEERING - FINAL | N/A | Not Inspected | ||
| SIGN - FINAL | N/A | Not Inspected | ||
| 11/27/2001 | MECHANICAL - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection 0000*INSPECTION ON EIGHT HEATERS ONLY. |
| 11/30/2001 | ELECTRIC - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection 0000*PARTIAL PENDING INSTALLATION OF FINAL 9 HTRS. |
| 11/30/2001 | ELECTRIC - ABOVE CEILING | N/A | Partial Approval | IVRS - Inspection 0000* |
| 11/30/2001 | ELECTRIC - FINAL | N/A | Not ready for Inspection | IVRS - Inspection 0000* |
| 12/06/2001 | PLUMBING - FINAL | N/A | Partial Approval | IVRS - Inspection 0000*1.) PERMIT CALLS FOR 17 INFRARED HEATING UNITS CONTRACTOR HAS INSTALLED UNITS 10-17 ONLY AT THIS TIME UNITS 1-9 TO BE INSTALLED IN THE FUTURE. IF THESE UNITS ARE NOT TO BE INSTALLED, REVISE AND STAMP PLAN ACCORDINGLY SO WE CAN FINAL THIS PERMIT. IF PLANNING TO INSTALL OTHER NINE UNTS. SOME ACTION MUST BE TAKEN WITHIN 180 DAYS OR PERMIT WILL EXPIRE 2.) INFRARED HEATERS NUMBERS 10-17 OK OK FOR GAS THESE UNITS ONLY 3.) UCC LEFT AT METER. |
Completed Inspections
Permit Status: Withdrwn
Permit Number: T01CM04421
Permit Description: ADDITION:INSTALLATION OF 17 INFRARED HEATING UNITS TO WAREHOUSE SUSPENDED FROM ROOF STRUCTURE
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/27/2001 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000*1) MEDIUM PRESSURE GAS TO EIGHT HEATERS OK PRESSURE TEST OK REMEMBER, WELD PIPE AND MEDIUM PRESSURE PIPING REQUIRES 60# TEST FOR 30 MINUTES. 2.) PIPING OK. |
| 12/02/2001 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection 0000*1.) VENT MUST BE FULL SIZED AND CONSTRUCTED OF APPROVED GAS MATERIALS 2.) VENT TERMINATION MUST BE TURNED DOWN AND SCREENED FOR BUG PROTECTION. |
| 12/05/2001 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*INSPECTION ON EIGHT HEATERS ONLY REMAINING NINE HEATERS TO GO ON A SEPERATE PERMIT. |