Permit: T01CM04111
Permit Details
Apply Date:
08/22/2001
Applicant:
DAVID MAJOR
Description:
SFR:NEW
Permit Reviews
Permit Number - T01CM04111
Permit Status: C of o
Permit Description: SFR:NEW
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/22/2001 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 10/16/2001 | COMPLETED |
| 11/26/2001 | RESUBMITTAL | 12/11/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM04111
Permit Status: C of o
Permit Description: SFR:NEW
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/22/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM04111
Permit Description: SFR:NEW
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/30/2002 | PLUMBING - YARD WTR LINE/TEST | HPEDROZA | Approved | IVRS - Inspection 0000* |
| 02/01/2002 | ELECTRIC - UFER | FGREER | Approved | IVRS - Inspection 0999* |
| 02/04/2002 | PLUMBING - ROUGH, SOIL | HPEDROZA | Approved | IVRS - Inspection 0000*/ 1) NEED TO INSPECT P-TRAPS FOR GUEST SUITE AT TOP-OUT PLUMBING INTERMEDIATE. OK TO BACK FILL REST OF HOUSE |
| 02/13/2002 | BUILDING PRE-SLAB | MTESTER | Approved | IVRS - Inspection 0000*/ 1) WRAP ALL ABS PIPING THRU CONCRETE LEVEL. RESULTS OF PREVIOUS INSPECTION NOT ON JOB SITE. PLEASE PROVIDE THEM |
| 03/08/2002 | FRAMING | MTESTER | Approved | IVRS - Inspection 0000* |
| 03/14/2002 | ROOF NAILING | FGREER | Approved | IVRS - Inspection 0000* |
| 03/15/2002 | EXT METAL CLIPS/EXT SHEATHING | FGREER | Approved | IVRS - Inspection 0000*/ 1) BY INTERMEDIATES PROVIDE LEG BOLTS AT PORCH IN FRONT 2) ASLO AT POST AT BACK PORCH SEE DETAIL D-4/10 |
| 04/03/2002 | MECHANICAL - INTERMEDIATE | MTESTER | Approved | IVRS - Inspection 0000* |
| 04/03/2002 | ELECTRIC - INTERMEDIATE | MTESTER | Approved | IVRS - Inspection 0000* |
| 04/11/2002 | PLUMBING - GAS PRESSURE TEST | EDURAZO | Approved | IVRS - Inspection 0000* |
| 04/11/2002 | PLUMBING - INTERMEDIATE | EDURAZO | Approved | IVRS - Inspection 0000* |
| 05/03/2002 | STUCCO MESH | FGREER | Approved | IVRS - Inspection 0000* |
| 05/06/2002 | ELECTRIC - TEMPORARY SERVICE | FGREER | Approved | IVRS - Inspection 0000* |
| 05/06/2002 | ELECTRIC - CABLE DROP | FGREER | Approved | IVRS - Inspection 0000* |
| 05/06/2002 | SHEET ROCK NAILING | FGREER | Approved | IVRS - Inspection 0000* |
| 06/18/2002 | PLUMBING - FINAL | MTESTER | Approved | IVRS - Inspection 0000* |
| 06/26/2002 | PERMIT FINALED | FGREER | Approved | |
| 06/26/2002 | MECHANICAL - FINAL | FGREER | Approved | IVRS - Inspection 0000* |
| 06/26/2002 | ELECTRIC - FINAL | FGREER | Approved | IVRS - Inspection 0000* |
| 06/26/2002 | BUILDING - FINAL | FGREER | Approved | IVRS - Inspection 0000* |