Permit: T01CM03263
Permit Details
Status:
C of o
Type:
COMMERCIAL ALTERATION
Address:
2443 N CAMPBELL AV
Address NEW:
2443 N CAMPBELL AV
Apply Date:
07/02/2001
Applicant:
N/A
Description:
TI:COFFEE SHOP: CHANGE OF OCCUPANCY,M-RETAIL TO A2-RESTAURANT................................................................................................................. 50' x 51" SPACE, METAL STUDS W/ GYP BD, VERIFY 2-HOUR FIRE BARRIER BETWEEN TENANTS.
Contractors:
- INTERIORS WITH IMAGINATION ,
Permit Reviews
Permit Number - T01CM03263
Permit Status: C of o
Permit Description: TI:COFFEE SHOP: CHANGE OF OCCUPANCY,M-RETAIL TO A2-RESTAURANT................................................................................................................. 50' x 51" SPACE, METAL STUDS W/ GYP BD, VERIFY 2-HOUR FIRE BARRIER BETWEEN TENANTS.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/02/2001 | COMMERCIAL TI | 07/09/2001 | COMPLETED |
| 07/09/2001 | RESUBMITTAL | 07/09/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM03263
Permit Description: TI:COFFEE SHOP: CHANGE OF OCCUPANCY,M-RETAIL TO A2-RESTAURANT................................................................................................................. 50' x 51" SPACE, METAL STUDS W/ GYP BD, VERIFY 2-HOUR FIRE BARRIER BETWEEN TENANTS.
Total Completed Inspections - 16
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/17/2001 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) OK TO BACKFILL 3.) P.O.C. OR NEW BUILDING DRAINS TO EXSISTING BLDG DRAINS OK 4.) U.G. COPPER LOOP ARE OK NOTE: SEPARATE HOT WATER SO THERE WILL BE 5.) NO TRANSFER OR HEAT. 6.0 NOTE: WILL REQUIRE AN APPROVED DRAWING ON WASTE AND VENT SYSTEM PRIOR TO INTERMEDIATE INSPECTION. |
| 07/23/2001 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 07/23/2001 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000*1.) WASTE & VENT SYSTEM IS OK 2.) WATER DISTRIBUTION IN PLDG. WALLS ARE OK 3.) OK FOR DRYWALL UPON BLDG. INSPECTORS APPROVED. 4.0 OK FOR GRID. |
| 07/23/2001 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | |
| 07/23/2001 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | OK WALLS |
| 07/23/2001 | FRAMING | EMONAHAN | Approved | |
| 07/25/2001 | SHEET ROCK NAILING | EMONAHAN | Approved | |
| 08/10/2001 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
| 08/10/2001 | SIGN - FINAL | JSONKIN | Approved | IVRS - Inspection 0000* |
| 08/12/2001 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection 0000*OK FINAL. |
| 08/13/2001 | PERMIT FINALED | FIRE | Approved | |
| 08/13/2001 | HEALTH DEPT - FINAL 724-7908 | HEALTH | Approved | |
| 08/13/2001 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 08/13/2001 | PLUMBING - PROGRESS | TRINIVJR | Approved | |
| 08/13/2001 | BUILDING - FINAL | AMATHIES | Approved | |
| 08/13/2001 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved |