Permit: T01CM03236
Permit Details
Apply Date:
06/28/2001
Applicant:
SIERRA PACIFIC BUILDING INC ,
Description:
TOWNHOME:TD#14-90-26
Contractors:
- SIERRA PACIFIC BUILDING INC ,
Permit Reviews
Permit Number - T01CM03236
Permit Status: Final
Permit Description: TOWNHOME:TD#14-90-26
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/28/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 06/29/2001 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T01CM03236
Permit Description: TOWNHOME:TD#14-90-26
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/17/2001 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) HCS CONNECTION IS OK 3.) OK TO BACKFILL TRENCH. |
| 07/23/2001 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection 0999*SEE WRITE UP ON UNIT 2809 ALSO THE #4 UFER ON THIS LOT IS TO BE TIED TO A 20' LENGTH OF REBAR AND THE #4 COPPER GOES ON THE BOTTOM OF THE ACORN CLAMP |
| 07/23/2001 | BUILDING PRE-SLAB | EMONAHAN | Approved | |
| 07/23/2001 | EXCAVATION/LAYOUT REBAR & ZON | EMONAHAN | Approved | |
| 09/25/2001 | ROOF NAILING | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 10/02/2001 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 10/02/2001 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 10/08/2001 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
| 10/09/2001 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 10/17/2001 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
| 10/29/2001 | SHEET ROCK NAILING | EMONAHAN | Approved | PA NEED EXTRA LAYER 1/2" UNDERSTAIRS. |
| 11/01/2001 | STUCCO MESH | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 11/30/2001 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000*OK TO CLEAR. |
| 12/17/2001 | PLUMBING - YARD WTR LINE/TEST | JMILITEL | Approved | IVRS - Inspection 0935*WATER LINE STILL NOT EXPOSED. PLEASE EXPOSE CONNECTION AT BLDG. & EXPOSE A FEW SECTIONS OF PIPE TO SEE PROPER BURIAL DEPTH. PAY REINSPECTION FEE PRIOR TO NEXT INSPECTION. |
| 02/11/2002 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) PLBG. FINAL IS OK 2.) OK FOR C OF O. |
| 02/14/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
| 02/28/2002 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000*OK C OF O. |
| 02/28/2002 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 04/02/2002 | PERMIT FINALED | DSANTACR | Approved | |
| 04/02/2002 | ELECTRIC - TEMPORARY POLE | DSANTACR | Approved |