Permit: T01CM02970
Permit Details
Apply Date:
06/13/2001
Applicant:
MARTINEZ HECTOR M & JUANITA D &
Description:
ADDITION:BEDROOM
Permit Reviews
Permit Number - T01CM02970
Permit Status: Expired
Permit Description: ADDITION:BEDROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/13/2001 | RESIDENTIAL BLDG/ZONING/FLOOD | 07/09/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM02970
Permit Status: Expired
Permit Description: ADDITION:BEDROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/13/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T01CM02970
Permite Description: ADDITION:BEDROOM
Total Outstanding Inspections - 9
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EXCAVATION/LAYOUT REBAR & ZON | N/A | Not Inspected | ||
| BUILDING PRE-SLAB | N/A | Not Inspected | ||
| ROOF NAILING | N/A | Not Inspected | ||
| FRAMING | N/A | Not Inspected | ||
| STUCCO MESH | N/A | Not Inspected | ||
| SHEET ROCK NAILING | N/A | Not Inspected | ||
| ELECTRIC - INTERMEDIATE | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| 08/09/2001 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection 0999*/ 1) NO PREVIOUS INSPECTIONS 2) CONCRETE IN WATER CLOSET DRAIN 3) NO COMBUSTION RELIEF FOR WATER HEATER 4) WATER HEATER FLUE TOUCHING COMBSUTIBLE MATERIALS 5) NO HEAT PROVIDED TO ADDITION 6) PROVIDE POSITIVE PITCHE TO SEWER LINE 7) ELECTRICAL PANE NOT PROTECTED AT CIRCUIT BREAKERS 8) FRAMING EXPOSED AT WEST WALL 9) MOVE WATER HEATER OUTSIDE CANNOT BE IN BEDROOM 10) EXPOSE EVERYTHING THAT WAS DONE 11) REVISE PLAN ASBUILT, EXPOSE ELECTRICAL AND REMOVE ALL PLUMBING FROM BATHROOM 12) LICENSED CONTRACTOR REQUIRED FOR ALL WORK |