Permit: T01CM02416
Permit Details
Apply Date:
05/18/2001
Applicant:
STANTEC
Description:
NEW:OSCO DRUG
Contractors:
- LANG CONSTRUCTION INC , W J
Permit Reviews
Permit Number - T01CM02416
Permit Status: C of o
Permit Description: NEW:OSCO DRUG
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/07/2002 | REVISION | 01/15/2002 | COMPLETED |
05/18/2001 | SITE | 06/15/2001 | COMPLETED |
05/21/2002 | REVISION | 05/21/2002 | COMPLETED |
07/10/2001 | RESUBMITTAL | 07/18/2001 | COMPLETED |
07/26/2001 | 3RD PARTY REVIEW-COMMERCIAL | 10/29/2001 | COMPLETED |
11/30/2001 | REVISION | 12/20/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM02416
Permit Description: NEW:OSCO DRUG
Total Completed Inspections - 41
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/17/2001 | LANDSCAPE - FINAL | PGILBERT | Approved | Check for existing native plants preserved to qualify for exception. (Comment made on 9/17/01) Note: This site has not been inspected. |
11/16/2001 | ELECTRIC - TEMPORARY POLE | DSANTACR | Approved | IVRS - Inspection 0000*OK TO CLEAR TEMP POLE OK CABLE DROP. |
12/17/2001 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection 0000* |
12/18/2001 | STEM WALL/RETAINING WALL | DWITT | Approved | IVRS - Inspection 0000* |
12/19/2001 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL AIR TEST OF 5LBS IS OK 2.) OK TO BACKFILL TRENCH. |
12/21/2001 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000*1.) 2 1/2" U.G. WATER SERVICE TEST OF 60LBS IS OK. 2.) 2 1/2" WATER SERVICE IS STUBBED OUT OF BLDG. ONLY. |
12/21/2001 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* |
12/24/2001 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
12/28/2001 | REINFORCED MASONRY PRE-GROUT | EMONAHAN | Approved | IVRS - Inspection 0000$PA @ W. 1/2 NORTH SIDE 1 SOUTH END. |
01/09/2002 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000* |
02/04/2002 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
02/14/2002 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
02/14/2002 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
02/22/2002 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
02/22/2002 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
02/26/2002 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
02/26/2002 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000* |
02/26/2002 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000*1.) RAIN LEADER WATER TEST ISOK 2.) GAS PRESSURE TEST IS OK 3.) OK FOR GRID & HARD LID. |
03/05/2002 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
03/20/2002 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | |
03/20/2002 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000* |
03/20/2002 | ELECTRIC - ABOVE CEILING | RMAJUTA | Approved | IVRS - Inspection 0000* ABOVE CEILING NEED TO SEE J-BOX INSTALLS AT GRID CEILING AT FRONT OF STORE. |
03/20/2002 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection 0000* |
03/22/2002 | ELECTRIC - TEMPORARY SERVICE | JORTA | Approved | OK TO CLEAR FOR TEMP. POWER SUBJECT TO POSTING BOND. |
04/01/2002 | PLUMBING - FINAL | TRINIVJR | Approved | 1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES OK 3.) FINAL CONNECTION TO BACKFLOW PREVENTERS AND METER IS OK 4.) PLBG. FINAL IS OK 5.) OK FOR C OF O. 6.) NOTE: FILM PROCESSOR HAS NOT BEEN INSTALLED. @ THIS TIME. |
04/17/2002 | ENGINEERING - FINAL | DROBERTS | Approved | |
04/25/2002 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000*OK C OF O. |
04/29/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000* OK FOR C OF O. |
04/29/2002 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
04/30/2002 | FIRE - FINAL | LTHOMAS | Approved | |
04/30/2002 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
05/23/2002 | SIGN - FINAL | DJOHNSTO | Approved | IVRS - Inspection 0000* |
05/29/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | |
05/29/2002 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
05/29/2002 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
05/29/2002 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
05/29/2002 | ELECTRIC - CABLE DROP | DSANTACR | Approved | |
05/29/2002 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | |
05/29/2002 | U VALUE FOR WINDOW | AMATHIES | Approved | |
05/29/2002 | BUILDING PRE-SLAB | AMATHIES | Approved | |
06/04/2002 | PERMIT FINALED | AMATHIES | Approved |