Permit: T01CM02152
Permit Details
Apply Date:
05/04/2001
Applicant:
CAPPS, ANTHONY G
Description:
RETAIL: AUTO SHOP
Architects:
- CAPPS, ANTHONY G
Contractors:
- DAMITIO CONSTRUCTION INC ,
Permit Reviews
Permit Number - T01CM02152
Permit Status: C of o
Permit Description: RETAIL: AUTO SHOP
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/04/2001 | 3RD PARTY REVIEW-COMMERCIAL | 09/25/2001 | COMPLETED |
08/24/2001 | SITE | 09/21/2001 | COMPLETED |
09/21/2001 | RESUBMITTAL | 10/01/2001 | COMPLETED |
11/07/2001 | REVISION | 11/29/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM02152
Permit Description: RETAIL: AUTO SHOP
Total Completed Inspections - 36
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/31/2001 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000*1.) U/G CONNECTION TO REBAR OK. |
11/05/2001 | STEM WALL/RETAINING WALL | DWITT | Approved | IVRS - Inspection 0000* |
11/08/2001 | PLUMBING - SEWER HCS CONNECT | FMCCLURE | Approved | IVRS - Inspection 0000* |
11/20/2001 | REINFORCED MASONRY PRE-GROUT | DWITT | Approved | IVRS - Inspection 0000* |
11/20/2001 | EXCAVATION/LAYOUT REBAR & ZON | DWITT | Approved | IVRS - Inspection 0000* |
11/26/2001 | PLUMBING - YARD WTR LINE/TEST | FMCCLURE | Approved | IVRS - Inspection 0000* |
11/28/2001 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000* |
11/28/2001 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000* |
11/28/2001 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | IVRS - Inspection 0000*U/G PVC 40 FROM TEP TFMR. TO SES ON BLDG OK |
12/03/2001 | ROOF NAILING | DWITT | Approved | |
12/11/2001 | BUILDING PRE-SLAB | DWITT | Approved | IVRS - Inspection 0000* |
12/12/2001 | PLUMBING - ROUGH, SOIL | FMCCLURE | Approved | IVRS - Inspection 0000* |
12/12/2001 | FRAMING | DWITT | Approved | IVRS - Inspection 0000* |
12/13/2001 | STUCCO MESH | DWITT | Approved | IVRS - Inspection 0000* |
12/17/2001 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000* |
12/19/2001 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000* |
12/19/2001 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*1.) PVC DWV OK 2.) COPPER OVERHEAD AND IN WALLS OK 3.) HAVE MECHANICAL INSPECTOR LOOK AT CONDENSATE DRAINS BEFORE COVERING 4.) OK TO COVER WALLS AND CEILING. |
12/20/2001 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*INSPECTION ON CONDENSATE DRAIN LINE IN WALL OK TO COVER. |
12/20/2001 | SHEET ROCK NAILING | DWITT | Approved | IVRS - Inspection 0000* |
01/03/2002 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR CEILING TILES. |
01/04/2002 | BUILDING ABOVE CEILING | DWITT | Approved | IVRS - Inspection 0000*ADD HANGERS WITHIN 8" OF EAST WALL. |
01/08/2002 | ELECTRIC - TEMP POWER FOR TEST | MCAPISTR | Approved | OK TO CLEAR C/D ONLY. |
01/09/2002 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | IVRS - Inspection 0000* |
01/10/2002 | PLUMBING - FINAL | FMCCLURE | Approved | IVRS - Inspection 0000* |
01/15/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
01/15/2002 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000* |
01/15/2002 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000* |
01/15/2002 | BUILDING - FINAL | DWITT | Approved | IVRS - Inspection 0000* |
01/16/2002 | MECHANICAL - TEMP PWR FOR TEST | JMILITEL | Approved | |
01/16/2002 | PERMIT FINALED | FIRE | Approved | |
01/16/2002 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
01/16/2002 | PLUMBING - TEMP POWER FOR TEST | FMCCLURE | Approved | |
01/16/2002 | ELECTRIC - TEMPORARY POLE | MCAPISTR | Approved | |
01/16/2002 | BUILDING - TEMP POWER FOR TEST | DWITT | Approved | |
01/16/2002 | U VALUE FOR WINDOW | DWITT | Approved | |
01/16/2002 | EXT METAL CLIPS/EXT SHEATHING | DWITT | Approved |