Permit: T01CM02084
Permit Details
Apply Date:
05/01/2001
Applicant:
METRO PERMIT EXPRESS, INC
Description:
NEW:RETAIL SHELL ONLY
Contractors:
- BARCLAY GROUP CONSTRUCTION SERVICES L L C
Permit Reviews
Permit Number - T01CM02084
Permit Status: Final
Permit Description: NEW:RETAIL SHELL ONLY
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/18/2003 | REVISION | 05/01/2003 | COMPLETED |
05/01/2001 | 3RD PARTY REVIEW-COMMERCIAL | 08/20/2001 | COMPLETED |
08/20/2001 | RESUBMITTAL | 11/02/2001 | COMPLETED |
10/03/2002 | REVISION | 11/08/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM02084
Permit Status: Final
Permit Description: NEW:RETAIL SHELL ONLY
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/01/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T01CM02084
Permit Description: NEW:RETAIL SHELL ONLY
Total Completed Inspections - 39
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/12/2002 | ELECTRIC - UFER | RMAJUTA | Approved | 1.) 3/0 COPPER UFER TO 20' REBAR FOR SERVICE 2.) 3/0 UPPER UFER TO 20' REBAR WATER BOND. |
11/19/2002 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection 0000*A-C/1-4 |
11/26/2002 | ELECTRIC - INTERMEDIATE | JORTA | Approved | IVRS - Inspection 0000* |
12/04/2002 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection 0000*TOP OUT MAIN BLD & FRONT COLS. |
12/06/2002 | ELECTRIC - UNDERGROUND | JORTA | Approved | IVRS - Inspection 0000* 6 PANELBOARD LOCATION & ONE HOME PANEL APPROVEL |
12/09/2002 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000* 1.) ABS DWV UNDERGROUND OK WATER TEST ONE RISER TO TEN FEET OK 2.) BLDG DRAIN TO OUTSIDE BLDG OK WATER TEST OK 3.) OK TO BACKFILL. |
12/11/2002 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000*1-4/A-B.8; SLAB TO BE SAW CUT FOR COLS AT B2 & B3. |
12/31/2002 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
01/07/2003 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
01/14/2003 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
01/16/2003 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) HCS CONNECTION IS OK 3.) OK TO BACKFILL TRENCH. |
01/26/2003 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000*1.) REC'D LETTER APPROVING TYPE "L" YARDWATER OK OK TO COVER. 2.) ABS DWV THRU ROOF OK COPPER WATER OK PRESSURE TEST OK 3.) CLOSET FLANGES OK 4.) OK TO COVER ALL AREAS. |
01/26/2003 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000* |
02/11/2003 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
02/14/2003 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000*AREA #101 TOTAL SYSTEM. #102 TOTAL SYSTEM. AREA #106, UNITS ON ROOF CURBS, DROPS DOWN THRU ROOF ONLY NO SUPPLY/RETURN DUCT SYSTEMS IN SPACE. ALL ADDITIONAL WORK WILL BE COMPLETED ON FUTURE T.I.'S. |
02/14/2003 | PLUMBING - TEMP POWER FOR TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
02/14/2003 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000*1.) ABOVE CEILING IS OK FOR GRID & TILE. 2.) OK FOR TEMP POWER. |
02/14/2003 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | NOTES OK TO CLEAR SUBJECT TO BOND POSTING BY CONTR. AND APPROVAL OTHER INSPECTORS. HOUSE PANEL METER ONLY. |
02/14/2003 | BUILDING - TEMP POWER FOR TEST | AMATHIES | Approved | IVRS - Inspection 0000* |
02/14/2003 | BUILDING ABOVE CEILING | AMATHIES | Approved | IVRS - Inspection 0000* |
02/18/2003 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | IVRS - Inspection 0000* |
02/18/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
03/19/2003 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
03/19/2003 | NPPO - FINAL | PGILBERT | Approved | |
03/19/2003 | LANDSCAPE - FINAL | PGILBERT | Approved | |
03/19/2003 | ENGINEERING - FINAL | DROBERTS | Approved | |
03/19/2003 | PLUMBING - FINAL | TRINIVJR | Approved | 1.) PLBG FINAL IS OK 2.) OK FOR C OF O. |
03/19/2003 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000* |
03/19/2003 | ELECTRIC - TEMPORARY POLE | TRINIVJR | Approved | |
03/19/2003 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000* |
03/20/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000*MECHANICAL WILL BE COMPLETED ON T.I. |
04/10/2003 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
04/10/2003 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection 0000* |
04/11/2003 | FIRE - FINAL | LTHOMAS | Approved | |
04/11/2003 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
04/11/2003 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
04/11/2003 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
04/11/2003 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
05/01/2003 | PERMIT FINALED | AMATHIES | Approved |