Permit Details

Status:
Final
Type:
COMMERCIAL ALTERATION
Address:
221 E WETMORE RD
Address NEW:
221 E WETMORE RD
Apply Date:
04/20/2001
Applicant:
N/A
Description:
REMODEL:LASER TAG FACILITY
Contractors:
  • EPSTEIN FENTON L L C ,

Permit Reviews

Permit Number - T01CM01901
Permit Status: Final
Permit Description: REMODEL:LASER TAG FACILITY
Start Date Submittal Complete Date Status  
04/20/2001 3RD PARTY COMMERCIAL TI 08/15/2001 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T01CM01901
Permit Description: REMODEL:LASER TAG FACILITY
Total Completed Inspections - 18
Date Description Inspector Results Comments
09/06/2001 STEM WALL/RETAINING WALL EMONAHAN Approved NO STEMS ON JOB.
10/01/2001 EXT METAL CLIPS/EXT SHEATHING EMONAHAN Approved IVRS - Inspection 0000$NO SHEETING ON THIS JOB
10/01/2001 BUILDING PRE-SLAB EMONAHAN Approved IVRS - Inspection 0000$NO PRE-SLAB AS JOB
10/01/2001 EXCAVATION/LAYOUT REBAR & ZON EMONAHAN Approved IVRS - Inspection 0000*
10/19/2001 BUILDING ABOVE CEILING DWITT Approved IVRS - Inspection 0000*
10/19/2001 FRAMING DWITT Approved IVRS - Inspection 0000*
10/22/2001 RIGHT OF WAY - FINAL ENGINEER Approved
10/22/2001 SIGN - FINAL JYBARRA Approved IVRS - Inspection 0000*
10/23/2001 ENGINEERING - FINAL DROBERTS Approved
10/25/2001 MECHANICAL - ABOVE CEILING CWILLIAM Approved IVRS - Inspection 0000*
10/30/2001 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
10/30/2001 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
10/31/2001 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection 0000*
10/31/2001 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection 0000*1.) EXPOSED CONDUCTOR END OF FIXTURE 2.) NEED TO SEE STROBE SIREN BREIFING ROOM 3.) MISSING LIGHT BREIFING ROOM 4.) USE CORRECT BREAKER PP-3 5.) LABEL PANEL 6.) USE APPROVED WIRE MOLD PARTS AND TEMANATE CONDUIT TO END CAP FOR MAINTAINING MECHANICAL CONTINUITY 7.) EMERGENCY LIGHTING COVERED. 8.) WORKING CLEARANCE IN FRONT DISCONNECT HP-1 ROOF. 9.) SUPPORT SEALTITE.10.) LOOSE SEATITE FITTINGS 11.) CK EXIT LIGHT OPERATION.
11/02/2001 SHEET ROCK NAILING EMONAHAN Approved IVRS - Inspection 0000*
11/04/2001 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection 0000*OK FINAL.
11/05/2001 BUILDING - FINAL EMONAHAN Approved IVRS - Inspection 0000*
11/06/2001 PERMIT FINALED EMONAHAN Approved